The ICS Triplex T8290C Trusted Output Power Distribution Unit Module is a robust and reliable power management component designed for Safety Instrumented Systems (SIS) and critical industrial automation applications.The module operates over a wide voltage range of 22 VDC to 120 VDC and can handle a maximum supply current of 60 A. Power is supplied via two M6 x 25 mm positive studs, while 0 V reference connections are provided through BLZ two-part terminals to maintain consistent grounding and system integrity. Three 6-way AMP MATE-N-LOK connectors deliver power outputs, with additional 0 V reference connections via 5-way BLZ terminals for reliable load connections.Designed to accommodate conductors from 0.5 mm² to 2.5 mm², the T8290C operates efficiently in temperatures ranging from 0 °C to +60 °C (+32 °F to +140 °F). Its durable construction and trusted design ensure high reliability, uninterrupted power distribution, and enhanced safety in high-integrity control systems.With ICS Triplex engineering standards, the T8290C Trusted Output Power Distribution Unit Module is ideal for maintaining continuous system operation and safeguarding critical automation equipment.
At a Glance: Technical Metrics
Model: T8290C
Product Type: Trusted™ Output Power Distribution Unit Module
System Compatibility: Trusted™ TMR control systems
Voltage Range: 22 Vdc - 120 Vdc
Supply Current: 60 A max
Field Device Support:
- Solenoids
- Relays
- Contactors
- Alarm devices
Supply Connection: +ve 2-off M6 x 25 mm studs
0 V Reference Connector (not 0 V return): BLZ 2-part terminal
Power Output (3-off): 6-way AMP MATE-N-LOK connector
0 V Reference Connector (3-off): 5-way BLZ two-part terminal
Conductor Clamping Range: 0.5 mm2 to 2.5 mm2
Operating Temperature: 0 °C to +60 °C (+32 °F to +140 °F)
Supports up to three Trusted Sourcing Output Modules.
Dual stud power connection for either single or dual feed.
0 V module reference via BLZ 2-part connectors.
Broad Industrial Applications
- Deep-Water Oil & Gas Production Facilities: Specifically engineered for rugged offshore and marine environments, the T8290C maintains complete operational stability under extreme thermal shifts, high vibration, and salt-mist exposure on deep-sea drilling platforms and floating production storage structures.
- Emergency Shutdown Systems (ESD): Built to execute high-priority trip actions without lag, the T8290C drives rapid, deterministic control commands directly to emergency isolation valves, solenoids, and fuel-cut off relays, protecting heavy plant assets from cascading mechanical failures.
- High-Availability Distributed Control Systems (DCS): Functioning within vast decentralized control architectures, this module bridges raw field instrumentation networks with overarching supervisory databases, enabling continuous process tuning in power plants and large-scale manufacturing facilities.
Hot Tags: t8290c; ICS Triplex T8290C; T8290C pdf; T8290C datasheet; T8290C manual; T8290C sell; T8290C new; T8290C ICS Triplex
Main Features And Advantages
- Sacrificial Overcurrent Shielding: To protect the underlying silicon from catastrophic field spikes, the T8290C uses replaceable fuses for overload and short-circuit protection, instantly blowing an isolated link if an external valve wire shorts out.
- Actuator Power Apportionment Grid: The T8290C distributes 24 VDC field power to Trusted digital output channels, functioning as a heavy-current terminal routing hub that safely relays actuation voltage down to individual field devices.
- Back-EMF Cascade Blockage: By trapping electrical transients directly at the sub-terminal block, the unit helps prevent propagation of field-side electrical faults, sheltering vulnerable downstream instrumentation.
- Structured Multi-Rail Geometry: Eliminating erratic cross-cabinet jumpers, the T8290C provides structured and protected field power routing, establishing clean physical separation between parallel digital output branches.
- Grouped Circuit Boundary Hardening: The internal copper trace design of the T8290C enhances fault isolation between output circuit groups, ensuring that a physical ground fault on one plant sector does not compromise adjacent live safety subroutines.
IsICS Triplex T8290C not the part you are wanting?
Check out the rest of our website to see what else we have to offer!
Recommended products
| 31082010 | MT308B1-R1C1 | Siemens 6RY17010AA04 |
| Yaskawa SGMRS-12A2B-YR11 | Allen Bradley 183-18-1014 | A06B-6110-H030 |
| NXCLD2M1-18-00200 | K800PB/G-018-4/0.500 UN5 | 284D-FVD7P6Z-25-CR-3-SB |
| Yaskawa CIMR-G5A27P5 | DAG75 | 3095MA23ABA13AA0000BC2 |
| IVUPRGX25 | QAMC14178ST | RFB204C |
| V91600TF-B | 5068-0029 | MGF63-100 |
| EVISTO10 | LPJ7MA-WTC3-XXX | GT2705-VTBD |
| AQ240F-04-00 | R60D26DT90L4 | XTL-03-B-10 25-1000PSI |
| VBM3538-S | Honeywell FYQLA1-140R-1 | 800-5838-4 |
| 0135966 NMRV/075 B3-6-7-8 | ER100 | 5RK90GU-CWM |
| 0305AC32B11B4 | Yokogawa UR1800 | STD920Z-E2N00000-K-XX |
| Siemens 6SN1145-1AA01-0AA2 | OU20-35-A7 | FDS60 |
| FREQROL-A200 | CRDNG-80-80-PPV-A | ST3000 STD920Z-E2N00000-K3-E1U1 |
| F60043000R | TANKS6LUV | MC1K-U015V PY0A015N0XXXC00 |
| PG51-19-E-27-VE | 704XX815 | Nov-53 |
| FG-06-32-14 | Allen-Bradley 1791-0A16/B | DEUBLIN 1154-003-137 |
| DT20-P214BS03 DT20 | NUS-A025PA-1 Rev 3/SUM2000-752-01 | 233E227 58-031-015 |
| SAF-70-QREG-301914 | PVQ13A2R-SE1S-20CG30 | AR-IPC3SP |
| CK3-8-15 | D405-B070-PT-D9 | DVT545 |
| G034058040 | 34150523 SK12.000 | DEUBLIN 1154-003-137 DS, RTR M12X1.25 LH PT13 |
Connect with Us & Request a Quote
Let's Connect & Automate!
Your reliable partner for premium PLCs, HMIs, Drives, and Sensors.
Manager: Vicky
📬 [sales7@apterpower.com] | 📞 [+8618030175807] | 📍 [Siming District, Xiamen City, Fujian Province]
⚡ Fast Shipping. ⚙️ Genuine Parts. 🤝 24/7 Support.