GE Multilin
GE Multilin Protection Relays and UR Modules
GE Multilin protection relays protect and monitor feeders, transformers, motors, generators, busbars and transmission lines. The product range includes modular UR protection relays and earlier Multilin relay families.
UR replacement hardware includes CPU, power supply, CT/VT input, digital I/O, transducer I/O and communication modules. Available options depend on the relay model, hardware generation and installed configuration.
For replacement purchasing, match the complete relay order code, module reference, hardware revision and firmware version. Legacy models such as 269, 369 and 745 use different product architectures and replacement requirements.
-
GE VMIVME-7750-746000 7750 Processor-Based VME (VMEbus) S...Manufacturer:GEread more
Part Number:VMIVME-7750-746000 7750
Origin:USA
Condition: brand new
Delivery Time: 3-5 days
HS Code: 8537101190
Shipping... -
General Electric 369-HI-R-M-0-0-0-E Motor Management RelayManufacturer:General Electricread more
Part Number:369-HI-R-M-0-0-0-E
Origin: USA
Condition: brand new
Delivery Time: 3-5 days
HS Code: 8537101190
Shipping... -
GE PCI-5565PIORC-110000 Reflective Memory PCI Node CardManufacturer:GEread more
Part Number:PCI-5565PIORC-110000
Origin:USA
Condition: brand new
Delivery Time: 3-5 days
HS Code: 8537101190
Shipping Weight:0.24kg... -
GE 269PLUS-100P-120 MULTILIN Motor Management RelayManufacturer:General Electric/GEread more
Part Number:269PLUS-100P-120
Origin:USA
Condition: brand new
Delivery Time: 3-5 days
HS Code: 8537101190
Shipping... -
GE UR5CH UR-5CH/UR5EH UR-5EH Transducer I/O ModuleManufacturer:General Electric/GEread more
Part Number:UR5CH UR-5CH/UR5EH UR-5EH
Origin: USA
Condition: brand new
Delivery Time: 3-5 days
HS Code: 8537101190... -
GE UR6DV UR-6DV/UR6CV UR-6CV Digital I/O ModuleManufacturer:General Electric/GEread more
Part Number:UR6DV UR-6DV/UR6CV UR-6CV
Origin: USA
Condition: brand new
Delivery Time: 3-5 days
HS Code: 8537101190... -
GE UR8NH/UR8GH/UR8AH CT/VT ModuleManufacturer:General Electric/GEread more
Part Number:UR8NH/UR8GH/UR8AH
Origin: USA
Condition: brand new
Delivery Time: 3-5 days
HS Code: 8537101190
Shipping... -
GE UR8FV UR-8FV CT/VT ModuleManufacturer:General Electric/GEread more
Part Number: UR8FV UR-8FV
Origin: USA
Condition: brand new
Delivery Time: 3-5 days
HS Code: 8537101190
Shipping Weight:... -
GE UR9AH UR-9AH CPU ModuleManufacturer:General Electric/GEread more
Part Number: UR9AH UR-9AH
Origin: USA
Condition: brand new
Delivery Time: 3-5 days
HS Code: 8537101190
Shipping Weight:... -
GE 10096227G5 GGN32L4XXMFXXXX 3200A EntelliGuard TU Trip ...Manufacturer: General Electric/GEread more
Part Number: 10096227G5 GGN32L4XXMFXXXX 3200A
Origin: USA
Condition: brand new
Delivery Time: 3-5 days
HS Code: 8537101190... -
GE 151X1224CFG 31F257 GFOI Processor ModuleManufacturer: General Electric/GEread more
Part Number: 151X1224CFG 31F257 GFOI
Origin: USA
Condition: brand new
Delivery Time: 3-5 days
HS Code: 8537101190... -
GE 20X4584-10A 20X4584A4 20X4584A4SR Advanced Control BoardManufacturer: General Electric/GEread more
Part Number: 20X4584-10A 20X4584A4 20X4584A4SR
Origin: USA
Condition: brand new
Delivery Time: 3-5 days
HS Code: 8537101190...
Select a Multilin Relay by Protection Application
The protected electrical asset determines the relay application. Feeder, transformer, motor, generator, busbar and line protection require different measurement inputs, protection functions and control arrangements.
| Protected Asset | Representative UR Models | Main Selection Factors |
|---|---|---|
| Feeder | F35 / F60 | Overcurrent and ground-fault protection, feeder arrangement, breaker control and measurement requirements. |
| Transformer | T35 / T60 | Differential protection, winding arrangement, CT ratios and transformer protection functions. |
| Motor | M60 | Motor protection, thermal characteristics, starting conditions and associated measurement inputs. |
| Generator | G30 / G60 | Generator protection, grounding, current and voltage inputs and protection coordination. |
| Busbar | B30 / B90 | Bus differential protection, bus zones, CT configuration and station arrangement. |
| Transmission Line | D60 / L90 | Distance or line differential protection, communications, CT/VT inputs and tripping scheme. |
Application matching: A relay model identifies a protection family. The complete order code determines the installed hardware and optional functions. Verify the actual relay configuration before selecting replacement parts.
UR Family vs Legacy Multilin Relays
GE Multilin includes modular UR protection relays and earlier relay families. Their hardware construction, ordering codes and software requirements are different.
Multilin UR Family
UR relays use a modular platform with configurable processor, power, measurement, digital I/O and communication hardware.
The applicable options depend on the relay model, chassis configuration, hardware generation and firmware.
View a UR CPU Module269, 369 and 745 Series
These earlier motor and transformer protection relays use their own complete ordering structures. They are not UR modular relay chassis.
GE Vernova identifies these families as legacy products with discontinued manufacturing. Replacement or migration must follow the applicable product guidance.
Legacy replacement: GE Vernova identifies the 859 as a migration direction for certain earlier motor protection relays and the 845 for the 745 transformer series. Final replacement suitability depends on wiring, settings, application and the OEM migration requirements.
Types of Multilin UR Hardware Modules
UR replacement modules must match the target relay configuration. Hardware options vary by relay model and generation.
| Module Type | Hardware Function | Replacement Check |
|---|---|---|
| Power Supply | Provides control power to the relay and associated internal circuitry. | Confirm the specified control-power input option and relay hardware generation. |
| CPU / Processor | Executes protection and control logic and supports model-dependent communication functions. | Match CPU type, hardware generation, communication configuration and firmware compatibility. |
| CT / VT Inputs | Provides current and voltage measurement inputs for protection and metering. | Confirm the input option, installed CPU generation and supported relay configuration. |
| Digital I/O | Provides contact inputs and relay outputs for protection, control and auxiliary signals. | Match input type, output contact arrangement, terminal assignment and module code. |
| Transducer I/O | Supports selected analog measurement and transducer input/output functions. | Confirm the exact analog I/O option and associated settings. |
| Communications | Supports selected networking, inter-relay communications and process-bus interfaces. | Verify interface type, physical port configuration and supported firmware. |
Hardware options: Communication protocols, control-power voltage and I/O capabilities are model-dependent. A common GE Multilin family name does not establish identical specifications across the product range.
UR Hardware Replacement Matching
Before replacing a UR module, record the complete relay order code and the installed module identification. Check hardware compatibility and firmware before changing the relay configuration.
- Relay model: Identify the complete F60, T60, M60, G60 or other UR model reference.
- Order code: Record the full relay catalog and installed hardware options.
- Module identification: Match the exact UR module code, visible revision and installed slot.
- CPU generation: Confirm the existing processor hardware type and supported firmware.
- CT/VT compatibility: Check the measurement module against the target CPU and relay hardware.
- Settings: Preserve approved relay settings and project configuration files.
- Commissioning: Follow the applicable OEM replacement and functional-test procedures.
GE Multilin UR9HH CPU module. Verify the complete hardware identification before replacement.
Firmware compatibility: Newer UR firmware releases do not necessarily support older CPU hardware. For example, GE Vernova UR 8.2x release notes identify support for T, U, V and W CPU types and exclude several earlier processor generations.
EnerVista UR Setup: The configuration software version must match the intended firmware. Settings conversion and hardware changes should follow the applicable release notes and approved relay-maintenance procedure.
Firmware, Lifecycle and Parts Availability
GE Multilin hardware options and firmware platforms have different lifecycle statuses. A supported UR relay model may contain an older module option that is no longer manufactured.
Technical Resources and Related Multilin Parts
Frequently Asked Questions
No. The UR family uses a different hardware architecture from earlier 369 and 745 protection relays. Match replacement hardware to the specific relay family or follow an approved migration path.
Not every CPU generation supports newer firmware. GE Vernova's UR 8.2x release notes specify T, U, V and W CPU compatibility and exclude earlier CPU types. Check the release notes for the firmware version being installed.
Yes. The processor and CT/VT module configuration must be supported by the target relay hardware and firmware. Check the complete order codes, hardware revision and applicable OEM instructions.
No. Control-power ratings, network ports and supported protocols depend on the relay family and ordered hardware. Verify the exact power-supply and communication options before replacement.
GE Vernova identifies the 859 as a replacement direction for legacy motor protection relays including the 369. Confirm the installed order code, wiring, functions, settings conversion and commissioning requirements before migration.
Match Your GE Multilin Relay Parts
Send the complete relay order code, installed module reference, hardware revision, firmware version if known, required quantity and destination country.
Send Your Multilin Order CodeRequest GE Multilin Parts
As one of the leading ge multilin manufacturers and suppliers, we warmly welcome you to wholesale discount ge multilin from our factory. All our products are with high quality and competitive price.
GE Multilin protection relays, Multilin relay replacement, GE Multilin spare parts
As one of the leading ge multilin manufacturers and suppliers, we warmly welcome you to wholesale discount ge multilin from our factory. All our products are with high quality and competitive price.
fiber optic products, badminton equipment, online marketplaces