Invensys Triconex

Triconex Safety-System Spare Parts

Triconex equipment includes main chassis, processors, I/O modules, communication hardware and external field-termination assemblies. Older units may bear the Invensys name; Triconex is now part of Schneider Electric. Tricon, Tricon CX, Trident and Tri-GP are distinct system families.

Replacing an installed part? Include its complete catalog number, system release, hardware revision, required quantity and a readable label photo. For network modules, specify the installed communication interface.

We check the condition and availability of each requested spare against the particular offer. Compatibility must follow the applicable system documentation.

Request a Triconex Part Quote
First 12345 Last

8110 Main Chassis: Confirm the Installed Rack

Triconex 8110 high-density main chassis
TRICON MAIN CHASSIS · 8110

The Tricon 8110 is a high-density main chassis, not a main processor. The Tricon v9–v11 planning guide describes positions for three main processors, power modules, communications and six logical I/O slot sets.

  • Identify the chassis model and the processor generation already installed.
  • Check the required backplane, power, expansion connections and slot allocation.
  • Do not use a chassis listing to infer the weight or specifications of an individual processor.

4351A TCM: Match the Tricon System Release

Triconex 4351A Tricon Communication Module front panel
TRICON COMMUNICATION MODULE · 4351A

The 4351A is a copper-Ethernet Tricon Communication Module (TCM) with serial interfaces. The Tricon v9–v11 planning guide lists the 4351A for Tricon v10.1 and later within its documented release scope; it does not list the 4351A for v10.0.

That guide also prohibits mixing older 4351/4352 TCMs with 4351A/4352A or later TCM families in one Tricon system. Check the precise system release, existing TCM models and current manufacturer release notices before replacing a network module.

Model-specific rule: the 4351A compatibility note is based on historical Tricon v9–v11 system documentation. Confirm current support and the approved configuration of the particular installed controller; it is not a blanket statement covering Tricon CX, Trident or Tri-GP hardware.

Triconex Hardware Identification by Purchase Task

Requested item Evidence to match Where to continue
Main chassis or processor Chassis type, processor generation, backplane and installed module arrangement Processor and chassis category
Digital or analogue I/O Module order code, field signal, connected termination and system generation I/O module category
TCM or other communication module Tricon system release, existing TCM model, ports, cable and network interface Communication category
Field termination or external terminator Mating I/O model, connector, field-wiring and terminal arrangement Termination category

Exact Spare or Engineered Replacement?

Exact-model maintenance

Compare the installed and offered manufacturer labels, revision and physical assembly. The quoted stock condition and included accessories require separate confirmation.

Different model or system generation

Confirm OEM replacement guidance, firmware, network configuration, field wiring and the safety function before approving a new model or migration.

For manufacturer information, refer to Schneider Electric's Triconex safety-system resources and the appropriate Tricon planning guide and product release notice for the installed release.

Triconex Chassis and Communication FAQ

Is the 8110 chassis the same part as a Tricon main processor?+

No. The 8110 is a main chassis that houses processor and other modules. Check whether the order is for the chassis, an individual processor or both; they have separate identities.

Does the 4351A TCM work in a Tricon v10.0 system?+

The historical Tricon v9–v11 planning guide lists 4351/4352 for v10.0 and 4351A/4352A from v10.1. Verify the exact system release and manufacturer support guidance before ordering.

Can a 4351 and 4351A TCM be installed in the same controller?+

The documented Tricon v9–v11 TCM mixing rule does not permit the older 4351/4352 and the 4351A/4352A or later families in the same system. Check the applicable release-specific manual before changing the communications configuration.

Which network details should accompany a 4351A replacement request?+

Include the installed Tricon release, existing communication module model, Ethernet or serial connections, module slot and any applicable firmware or project record. A nameplate photo helps confirm the requested variant.

Does purchasing a communication spare approve an SIS configuration change?+

No. The system owner or qualified safety engineer must assess firmware, communications, application and change-control requirements before installation and return to service.

Send Your Triconex Spare-Part Requirements

Send the complete part number, quantity, requested condition and destination. For chassis or communications replacements, include the installed Tricon release, existing module type and nameplate photo. We can check the availability and offer details of the specific item requested.

Request Triconex Part Availability

 

PLCleader is an independent industrial spare-parts supplier, not an authorized Schneider Electric, Triconex or Invensys representative or distributor. All trademarks belong to their respective owners. Offered condition, origin, available quantity, inspection evidence, warranty and delivery arrangements are confirmed in the individual quotation.

As one of the leading invensys triconex manufacturers and suppliers, we warmly welcome you to wholesale discount invensys triconex from our factory. All our products are with high quality and competitive price.

Disclaimer:

PLCleader sells new and surplus products and develops channels for purchasing such products. This website has not been approved or recognized by any of the listed manufacturers or trademarks.

PLCleader is not an authorized distributor, dealer, or representative of the products displayed on this website. All product names, trademarks, brands, and logos used on this website are the property of their respective owners. The description, explanation, or sale of products with these names, trademarks, brands, and logos is for identification purposes only and is not intended to indicate any association with or authorization from any rights holder.