SPA-ZC 402 provides connectivity to IEC 61850, SPA TCP/IP and Modbus TCP/IP Ethernet based protocols and standards. It acts as a communication adapter between the SPA bus and the IEC 61850-8-1 station bus. SPA-ZC 402 maps the SPA protocol interface to the IEC 61850-8-1 standard. This enables connecting products with optical SPA interface to IEC 61850 based networks in both new and retrofit installations.
Product specifications

- Part Number: SPA-ZC 402
- Manufacturer: ABB
- Type: Communication Adapter
- Supported Protocols: SPA-bus, Modbus, IEC 60870-5-103
- Input Voltage: 24-250 V AC/DC (typical)
- Communication Interface: Serial, RS-485
- Data Transfer Rate: Configurable, supports up to 9600 baud
- Operating Temperature: -25°C to +55°C
- Mounting: DIN rail or panel mount
The ABB SPA-ZC 402 is a communication adapter designed to interface ABB relays and protection devices with higher-level control and monitoring systems. This adapter enables the connection of protection relays to various communication protocols, such as Modbus and IEC standards, allowing for efficient data transfer and remote monitoring. It plays a critical role in enhancing communication between field devices and centralized control systems, ensuring reliable system integration.
Introduction
Using the SPA-ZC 402, an Intelligent Electronic Device (IED) with a fibre optic SPAbus can be connected to the Ethernet basedIEC 61850-8-1 station bus.IEC 61850 is the new standard for substationcommunication. Additionally to being a communication standard, it also supports generalsubstation automation functions as well as theengineering process SPA-ZC 402 also enables ethernet access toan IED using the SPA over TCP/IP and Modbus over TCP/IP.The SPA-ZC 402 acts as a communicationadapter between the SPA bus and the IEC61850-8-1 station bus. The SPA-ZC 402 maps the SPA protocol interface to the IEC61850-8-1 standard. This enables connectingproducts with optical SPA interface to IEC61850 based networks in both new and retrofit installations.More information on how to physically connect the device can be found in the chapter 5of the Installation and Commissioning manual. SPA-ZC 402 programming is describedin the Installation and commissioning manual, chapter 6, Engineering. As a prerequisite, you should understand thecommunication properties of the IED that isto be connected to Ethernet adapter. Thisinformation is available in the manual for theprotection IED in question.
Tests and conditions
Environmental tests and conditions
|
Recommended service temperature range |
-10...+55°C (continuous) |
|
Limit temperature range (short-term) |
-40...+70°C |
|
Transport and storage temperature range |
-40...+85°C according to the IEC 60068-2-48 |
|
Dry heat test |
IEC 60068-2-2 |
|
Dry cold test |
IEC 60068-2-1 |
|
Damp heat test |
IEC 60068-2-30 |
Electromagnetic compatibility tests
| EMC immunity test level meets the requirements listed below | |
| 1 MHz burst disturbance test, class III Common mode Differential mode |
According to the IEC 60255-22-1 2.5 kV 1.0 kV |
| Electrostatic discharge test, class IV For contact discharge For air discharge |
According to the IEC 6100-4-2 and IEC 60255-22-2 8 kV Not applicable |
(keywords:spa zc 402; abb SPA-ZC 402; spa zc 402 pdf; datasheet SPA-ZC 402; spa zc 402 manual)
Numerous advantageous brands
- Bently Nevada TSI
Bently Nevada 3500 Series Monitor system, Bently Nevada 3300 Series Monitor system
Modules/Chassis/I/O Module, Power Supply Module/Proximitor Sensor/ Programming Cable
- GE/General Electric PLC
GE IC695, IC698, GE IC694, IC697, GE IC754, IC752 QuickPanel, GE IC660, IC600 Seriex Six, GE IC610, IC620 Series One, GE IC692 Series 90-20, GE IS200, IS215, GE DS200, DS3000/3800
- Invensys Foxboro DCS
Foxboro I/A Series System Module.Foxboro CP /Foxboro FBM , Foxboro Termination Assembly Module, Foxboro Baseplate
- InvensysTriconex DCS
Triconex Rack, Triconex Power Module, Processor Module, Input Module, Output Module, Tricon Communication Module TCM, Triconex Terminal Block, Triconex Cable
- Yokogawa PLC
Yokogawa CENTUM CS 3000 R3/Yokogawa CPU Module/Power Supply Module/ I/O Module/Cards
- Schneider PLC
Modicon, Quantum 140 System
- Hima PLC
CPU/Power Distribution Module/COPROCESSOR MODULE/INPUT MODULE/OUTPUT MODULE
Daily Recommendations
|
CI540 3BSE001077R1 |
KJ4001X1-CC1 12P0733X032 |
6ES7131-4BD01-0AA0 |
MC-TAOX52 51304335-275 |
|
CI590 3BHT340092R1 |
KJ4001X1-CC1 12P0733X042 |
6ES7132-0BL01-0XB0 |
MC-TAOY22 51204172-175 |
|
CI610 3BHT300003R1 |
KJ4001X1-CG1 12P1812X042 |
6ES7195-7HF80-0XA0 |
MC-TAOY25 51305865-275 |
|
CI615 3BHT300024R1 |
KJ4001X1-CH1 12P1811X032 |
6ES7307-1KA00-0AA0 |
MC-TDIA12 51304439-175 |
|
CI626A 3BSE005023R1 |
KJ4001X1-CK1 12P0732X162 |
6ES7315-1AF03-0AB0 |
MC-TDIA72 51303930-150 |
|
CI626V1 3BSE012868R1 |
KJ4001X1-HC1 12P0831X072 |
6ES7414-1XG02-0AB0 |
MC-TDID12 51304441-175 |
|
CI630 3BSE011000R1 |
KJ4001X1-JA1 12P1832X022 |
6ES7417-4XL04-0AB0 |
MC-TDIY22 51204160-175 |
|
CI680 3BSE007364R1 |
KJ4001X1-NA1 12P3373X012 |
6ES7421-1BL00-0AA0 |
MC-TDIY22 51204160-175 |
Is ABB SPA-ZC 402 not the part you are wanting?
Check out the rest of our website to see what else we have to offer!
Call For Best Price
|
Sales manager |
|
Whatsapp/Phone |
Skype |
|
Vicky |
Hot Tags: abb spa-zc 402 communication adapter, abb spa-zc 402 communication adapter manufacturers, suppliers, motor drives, photodiodes, linear motors, reducer motors, gears, synchronous motors