The three-phase voltage relay SPAU 130 CC-AA isintended to be used for overvoltage and undervoltage protection and supervision in distribution substations. The relay can also be used forovervoltage and undervoltage protection of generators, motors and transformers. Generally therelay measures the three phase-to-phase voltagesof the system but it can also be programmed forsingle-phase measurement.
Product specifications

Part Number: SPAU130C-AA
Manufacturer: ABB
Type: Three-phase voltage relay
Input Voltage Range: 100–240 V AC
Frequency: 50/60 Hz
Overvoltage Setting Range: Adjustable up to a maximum voltage limit
Undervoltage Setting Range: Adjustable for minimum voltage thresholds
Relay Contacts: 2 or more programmable outputs
Mounting Type: Panel mount
Operating Temperature: -10°C to +55°C
Power Supply: 24–110 V DC or AC supply, depending on configuration
The ABB SPAU130C-AA is a three-phase voltage relay designed to provide overvoltage and undervoltage protection in industrial power systems. It monitors voltage levels in three-phase networks and ensures the safe operation of electrical equipment by triggering alarms or protective actions when voltage anomalies are detected. The SPAU130C-AA is typically used in power distribution systems, industrial plants, and electrical substations, making it a critical component in maintaining the stability and safety of electrical operations.
Description of function
The combined overvoltage and undervoltagerelay SPAU 130 C is a secondary relay that isconnected to the voltage transformers of theprotected object. The relay generally measuresthe three phase-to-phase voltages of the system.On operating the relay trips the circuit breakerand/or provides alarm, in accordance with theselected functions and given configuration.
When one of the phase-to-phase voltage orseveral exceed the set start value U> of theovervoltage stage, the overvoltage stage startsdelivering a start signal SS1. When, at definitetime mode of operation, the set operate time t>or, at inverse time mode of operation, the calculated operate time t>, has expired, the overvoltagestage operates delivering a trip signal TS1. In thesame way the undervoltage stage starts delivering a start signal SS2 when the measured valuegoes below the start value U< and when the setoperate time t< has expired, the undervoltagestage operates, delivering a trip signal TS2.
The overvoltage and undervoltage relay is generally used as a three-phase relay. But by meansof a selector switch the relay can be configuredas a single phase relay.
The overvoltage stage can be given definite timecharacteristic or inverse time characteristic.When inverse time characteristic is selected twosets of curves named A and B are available.
Start and operation indicators

1. The relay module is provided with two operation indicator located in the right bottomcorner of the front plate of the relay module.One indicates operation of the overvoltagestage and the other operation of the undervoltage stage. Yellow light indicates that theconcerned stage has started and red light thatthe stage has operated (tripped).
With the SG2 software switchgroup the startand trip indicators can be given a latchingfunction, which means that the LEDs remainlit, although the signal that caused operationreturns to normal. The indicators are resetwith the RESET push-button. An unresetindicator does not affect the operation of therelay.
2. The yellow LED indicators (U12, U23 andU31) on the upper black part of the front plateindicate, when lit, that the correspondingvoltage value is currently being displayed.
3. The red IRF indicator of the self-supervisionsystem indicates, when lit, that a permanentinternal relay fault has been detected. Thefault code appearing on the display once afault has been detected should be recordedand notified when service is ordered.
4. The green Uaux LED on the front panel is litwhen the power supply module operates properly.
5. The LED indicator below a particular settingknob indicates, when lit, that the settingvalue of the knob is currently being displayed.
6. The LED of the SG1 switchgroup indicates,when lit, that the checksum of the switchgroup is currently being displayed.
(keywords:spau130c aa; abb SPAU130C-AA; SPAU130C-AA pdf; datasheet SPAU130C-AA; spau130c aa manual)
Numerous advantageous brands
- Bently Nevada TSI
Bently Nevada 3500 Series Monitor system, Bently Nevada 3300 Series Monitor system
Modules/Chassis/I/O Module, Power Supply Module/Proximitor Sensor/ Programming Cable
- GE/General Electric PLC
GE IC695, IC698, GE IC694, IC697, GE IC754, IC752 QuickPanel, GE IC660, IC600 Seriex Six, GE IC610, IC620 Series One, GE IC692 Series 90-20, GE IS200, IS215, GE DS200, DS3000/3800
- Invensys Foxboro DCS
Foxboro I/A Series System Module.Foxboro CP /Foxboro FBM , Foxboro Termination Assembly Module, Foxboro Baseplate
- InvensysTriconex DCS
Triconex Rack, Triconex Power Module, Processor Module, Input Module, Output Module, Tricon Communication Module TCM, Triconex Terminal Block, Triconex Cable
- Yokogawa PLC
Yokogawa CENTUM CS 3000 R3/Yokogawa CPU Module/Power Supply Module/ I/O Module/Cards
- Schneider PLC
Modicon, Quantum 140 System
- Hima PLC
CPU/Power Distribution Module/COPROCESSOR MODULE/INPUT MODULE/OUTPUT MODULE
Daily Recommendations
|
AI910S 3KDE175511L9100 |
3500/42M 140734-02 |
140CRP93200C |
6ES7131-4BD01-0AA0 |
|
AI930N 3KDE175513L9300 |
3500/42M 140734-02 |
140DAI74000 |
6ES7132-0BL01-0XB0 |
|
AI930S 3KDE175511L9300 |
3500/42M 176449-02 |
140DDI35300 |
6ES7195-7HF80-0XA0 |
|
AI931N 3KDE175513L9310 |
3500/42M 176449-02 |
140DDI35310 |
6ES7307-1KA00-0AA0 |
|
AI931S 3KDE175511L9310 |
3500/42M 176449-02 |
140DDM39000 |
6ES7315-1AF03-0AB0 |
|
AI950N 3KDE175523L9500 |
3500/44M 176449-03 |
140DDO35300 |
6ES7414-1XG02-0AB0 |
|
AI950S 3KDE175521L9500 |
3500/50M 286566-02 |
140DDO35310 |
6ES7417-4XL04-0AB0 |
Is ABB SPAU130C-AA not the part you are wanting?
Check out the rest of our website to see what else we have to offer!
Call For Best Price
|
Sales manager |
|
Whatsapp/Phone |
Skype |
|
Vicky |
Hot Tags: abb spau130c-aa three phase voltage relay, abb spau130c-aa three phase voltage relay manufacturers, suppliers, screws, battery chargers, seals, cables, blow molding machines, connectors