Allen Bradley 2711P-T15C22D9P is 2711P PanelView Plus 7 Performance Terminals, Touch Screen, 15 XGA, TFT Color, Ethernet DLR, 24V DC, Windows 10 IoT Core, Performance Model.
The 2711P-T15C22D9P model from Allen Bradley's Panelview Plus 7 series is a versatile performance terminal adaptable for various applications. This terminal features a 15-inch diagonal TFT color display, allowing for clear and vibrant graphical representations.
The Technical specifications for 2711P-T15C22D9P
Manufacturer: Allen Bradley
Product Type: Performance Terminal
Product Line: Panelview Plus 7
Part Number: 2711P-T15C22D9P
Weight 7.00 lbs (3.18 kg)
Display Type: TFT Color
Display Size: 15 Inches Diagonal
Operator Input Touch: Viewing Area (W x H) 304 mm x 228 mm
Display Resolution : 1024 x 768 XGA, 18-Bit Color Graphics Aspect Ratio 4:3
System Memory: 512 MB of RAM
User Memory: 512 MB of Storage
Nominal Input Voltage: Rating 24 Volts DC
Input Voltage Range: 18 to 30 Volts DC
Power Consumption 50 Watts Maximum (2.1 Amps at 24 Volts DC)
We maintain an extensive, ready-to-ship inventory of Allen-Bradley PanelView HMI units, bridging the gap between modern high-performance systems and legacy infrastructure. Our catalog features the latest PanelView 5000 performance series, offering advanced widescreen displays and enhanced processing power for new Studio 5000-integrated projects, alongside the critical, often discontinued PanelView Plus 1250 line essential for maintaining existing production lines. Whether you are executing a facility-wide technology upgrade or urgently sourcing a replacement module like the 2711P-B12C15A1 to minimize downtime, we provide the verified hardware and technical expertise to ensure seamless integration. By combining global shipping capabilities with a deep focus on both new and obsolete components, we remain your reliable partner for keeping your plant floor operational and efficient.
Allen-Bradley PanelView HMI Series (Including 2711P-T15C22D9P) Overview
| Series | Typical Models | Lifecycle Status | Common Applications |
| PanelView 5000 | 2711P-T7C22D9P, 2711P-T10C22D9P, 2711P-T12W22D9P, 2711P-T15C22D9P | Active | New projects, Studio 5000 integrated control systems. |
| PanelView Plus 1250 | 2711P-B12C15A1 | Discontinued | Critical legacy infrastructure maintenance. |
Table Notes:
- Migration Note: For users operating on legacy PanelView Plus systems looking to modernize, we strongly recommend evaluating the migration paths to the current PanelView 5000 series to leverage enhanced performance and long-term hardware availability.
- Application Scope: While PanelView 5000 is optimized for Logix controller integration, PanelView Plus units remain the industry standard for established, mature automation environments requiring strict backwards compatibility.
Allen-Bradley PanelView HMI System: 2711P-T15C22D9P High Performance & Maintenance Series
- Input Voltage: 18...30V DC (Nominal 24V DC)
- Display Technology: TFT Active-Matrix Color LCD, White LED Backlight
- Operating Temperature: 0°C to 55°C (32°F to 131°F)
- Enclosure Ratings: NEMA/UL Type 12, 13, 4X, IP66 (Classified by UL)
- Communication Ports: Dual EtherNet/IP ports (supports DLR, linear, or star network topologies)

The following table summarizes the electrical load, touch interface, and hardware configuration specifications for each model:
| Product Image | Catalog Number | Series | Display Size | Touch Type | Typical Power (BTU/hr) | User Memory | Action |
![]() |
2711P-T7C22D9P | PanelView Plus 7 Perf. | 6.5-in | Analog Resistive | 38 - 51 BTU | 2 GB | Inquire Now! |
![]() |
2711P-T10C22D9P | PanelView Plus 7 Perf. | 10.4-in | Analog Resistive | 48 - 51 BTU | 2 GB | Inquire Now! |
![]() |
2711P-T12W22D9P | PanelView Plus 7 Perf. | 12.1-in | Analog Resistive | 49 - 60 BTU | 2 GB | Inquire Now! |
![]() |
2711P-T15C22D9P | PanelView Plus 7 Perf. | 15.0-in | Analog Resistive | 61 - 71 BTU | 2 GB | Inquire Now! |
![]() |
2711P-B12C15A1 | PanelView Plus 1250 | 12.1-in | Touch + Keypad | Approx. 67 BTU | 80 MB | Inquire Now! |
Notes:
- Touch Interface: The PanelView Plus 7 Performance series (T7, T10, T12W, T15) utilizes analog resistive touch screens with a 1-million-press actuation rating. The legacy 2711P-B12C15A1 model integrates both physical keypad and touch input for specific industry operation requirements.
- Power Consumption: The BTU values listed represent typical heat dissipation. Variations in the power range are dependent on the internal Series version (Series A or Series B) of the hardware.
- Memory Configuration: Modern Performance series units (Series B) provide 2 GB of non-volatile user storage, whereas the 2711P-B12C15A1 legacy model follows a different architectural storage configuration.
Choosing the Right HMI: Comparing 2711P-B12C15A1 and 2711P-T12W22D9P for Your Application
When evaluating system upgrades, choosing between the legacy PanelView Plus 1250 and the modern PanelView 5000 series is a critical decision. Below is a breakdown of how these two 12.1-inch benchmarks compare:
Legacy Benchmark: 2711P-B12C15A1 (PanelView Plus 1250)
- System Role: The established standard for mature automation environments requiring strict backwards compatibility.
- Software Ecosystem: Fully compatible with FactoryTalk View Machine Edition (ME) projects.
- Display Profile: Features a traditional 4:3 aspect ratio, widely used in existing control cabinets.
- Lifecycle Status: Discontinued/Legacy; ideal for maintenance and direct replacement of failed hardware to avoid complex system redesigns.
Performance Benchmark: 2711P-T12W22D9P (PanelView 5000)
- System Role: The next-generation solution for modern high-performance visualization.
- Software Ecosystem: Engineered specifically for the Studio 5000 View Designer environment, providing deeper integration with Logix controller tags.
- Display Profile: Features a modern 16:10 widescreen display, offering significantly more workspace for complex graphics and data visualization.
- Lifecycle Status: Active; recommended for new capital projects or facility-wide technology modernizations.
Technical Note on Migration: Transitioning from the 2711P-B12C15A1 to the 2711P-T12W22D9P involves moving from FactoryTalk View ME to Studio 5000 View Designer. We recommend verifying your physical installation cut-outs and reviewing your project's tag database prior to upgrade. Please contact our technical team if you require support with migration strategy or documentation for your specific project environment.
Product Lifecycle & Migration Path: Full Series (Featuring 2711P-T15C22D9P)
This table provides a comprehensive overview of current high-performance models and their direct technological predecessors.
| Current Active Model | Legacy Predecessor (Replaced) | Migration Context | Action |
| 2711P-T7C22D9P | 2711P-T7C6D8 / T7C6D9 | From PV Plus 6 to Plus 7 Perf. | Inquire Now! |
| 2711P-T10C22D9P | 2711P-T10C6D8 / T10C6D9 | From PV Plus 6 to Plus 7 Perf. | Inquire Now! |
| 2711P-T12W22D9P | 2711P-T12W6D8 / T12W6D9 | From PV Plus 6 to Plus 7 Perf. | Inquire Now! |
| 2711P-T15C22D9P | 2711P-T15C6D8 / T15C6D9 | From PV Plus 6 to Plus 7 Perf. | Inquire Now! |
| 2711P-T12W22D9P | 2711P-B12C15A1 (PV Plus 1250) | Migration to Wide-aspect Perf. | Inquire Now! |
Migration Risk Assessment & Pre-check Checklist
Before initiating hardware replacement, perform the following validation to mitigate operational risks:
- Physical Cutout Verification: The 2711P-B12C15A1 legacy unit features a keypad-touch hybrid design, while the 2711P-T12W22D9P Performance unit is a widescreen touch-only model. Verify that the existing panel enclosure cutout dimensions accommodate the widescreen display footprint; failure to do so will require mechanical metalwork.
- Software Project Retargeting: Legacy applications developed for 2711P-B12C15A1 must be re-targeted in FactoryTalk View Studio. Specifically, reconfigure the display resolution to match the 16:9 aspect ratio of the Performance series to prevent screen object distortion or clipping.
- Operating System Compatibility: Be aware that transitioning from legacy series to Series B Performance terminals involves a fundamental OS shift from Windows CE to Windows 10 IoT Core. Validate existing 3rd-party ActiveX controls or script dependencies for compatibility with the newer OS environment.
PanelView Plus 7 Performance 2711P-T15C22D9P: System Architecture & Integration
The PanelView Plus 7 Performance terminal acts as the central HMI node in factory floor operations. Its architectural design is engineered for seamless integration with control and information layers, supporting diverse applications ranging from discrete manufacturing to complex process control.

In high-speed discrete automation, the terminal functions as a critical node in the EtherNet/IP infrastructure, facilitating high-speed data exchange with Logix5000 controllers (such as ControlLogix or CompactLogix).
- Applicable Models: 2711P-T7C22D9P, 2711P-T10C22D9P, 2711P-T12W22D9P, 2711P-T15C22D9P.
- Architectural Advantage: Native support for DLR (Device Level Ring) topology ensures that the HMI monitoring interface remains operational even during a single communication path failure, significantly enhancing system fault tolerance.
Process Automation & Monitoring (Distributed System Integration)
For process industries such as chemical or food processing, these terminals are integrated into the PlantPAx system architecture, utilizing high-performance graphics and processing power to monitor analog loops and alarm logic.
- Applicable Model: 2711P-T15C22D9P (High-resolution, large-format display).
- Architectural Advantage: Integrated via FactoryTalk View Machine Edition software, supporting the real-time visualization of complex instrumentation and PID control loops, ensuring data transparency for operators during critical process stages.
Modernization & Migration (Architectural Integration)
For legacy system retrofits, the Performance series provides a robust migration path from older hardware to modern, secure architectural frameworks.
- Involved Models: 2711P-T12W22D9P as the recommended upgrade path for the 2711P-B12C15A1 (Legacy 1250 series).
- Architectural Advantage: Enables a smooth transition of existing HMI logic to the modern, secure framework supported by Windows 10 IoT Core, utilizing FactoryTalk View Studio for application re-targeting and feature integration.
Field Installation & Operational Procedures
- Mounting Integrity: Upon confirming the correct panel cutout via the prior assessment phase, insert the terminal into the enclosure and secure it using the provided mounting clips.
- Gasket Maintenance: Ensure the factory-installed gasket is seated firmly against the enclosure surface to maintain the specified IP66/IP69K protection rating.
- Corrosion Protection: For units with the BSHK suffix operating in harsh environments, verify that the enclosure and mounting hardware comply with ISA 71.04-2013 G3/CX standards.

Electrical Wiring & Grounding Standards
- EMC Grounding: Connect the terminal's Protective Earth (PE) lug directly to the cabinet's common ground bus using a short, low-impedance conductor to mitigate high-frequency electrical noise.
- Power Input: Supply power via shielded cables to comply with established electromagnetic compatibility (EMC) regulations.
- Port Protection: Ensure all unused communication ports are sealed with factory-provided protective caps to prevent debris ingress and accidental interference.

Network Physical Layer Implementation
- Cable Routing: Route all Ethernet cabling away from high-voltage AC lines or motor drives to ensure signal integrity.
- DLR Physical Setup: When deploying in a Device Level Ring (DLR) topology, ensure the cabling loop is physically completed by connecting the final terminal port back to the managed switch or the next logical device in the ring.
2711P-T15C22D9P Fault Diagnosis & Troubleshooting Procedures
Common Operational Faults
▷Touch Screen Unresponsiveness:
- If the touch input is unresponsive, verify that the protective film is correctly applied without air bubbles or debris.
- Clean the screen surface using a soft, non-abrasive cloth dampened with mild detergent; avoid industrial solvents that could degrade the overlay integrity.
▷DLR Network Communication Loss:
- When the HMI reports a "DLR Ring Fault," check the physical cabling at each node in the ring for loose connections or damaged insulation.
- Access the device web interface to verify that the "DLR Status" indicates a "Ring Normal" state; if a "Ring Fault" is active, isolate the segment between the two nodes where the link light is extinguished.
▷FactoryTalk View Runtime Stability:
- If the HMI experiences sudden application reboots, monitor the system logs via the terminal's diagnostic menu to check for "Memory Exhaustion" or "Critical Script Execution" errors.
- Verify that the background loading of external files (e.g., PDF viewer, ActiveX controls) does not exceed the internal DRAM capacity of the specific terminal model.
Diagnostic LED Indicators
Use the following reference table to interpret the status of the terminal based on the LED indicators located on the front/side panel.
| LED Status | Meaning | Action Required |
| Solid Green | Normal Operation | No action needed. |
| Flashing Red | Firmware or Kernel Fault | Power cycle the unit; if it persists, initiate factory recovery. |
| Solid Red/Amber | Boot Sequence Halt | Verify SD card/storage media seating and integrity. |
| No Link Light | Network Connectivity Loss | Check cable continuity and switch port configuration. |
Recovery Protocols
- Emergency Recovery (Safe Mode):If the OS fails to boot into the FactoryTalk environment, use the boot-time diagnostic menu to perform a "Factory Reset." Note that this operation clears all user-defined local configurations and application files.
- Hardware Integrity Check:For persistent display flickering or contrast abnormalities on the T12W/T15 series, perform a "Display Self-Test" via the Configuration Mode menus to rule out backlight driver failure.
Evolution & Architectural Transition: PanelView Series
To optimize system performance and ensure long-term support, industrial automation infrastructure is migrating from the legacy PanelView Plus 1250 architecture to the modern PanelView Plus 7 Performance platform. The following table illustrates the technological progression and architectural shift between these generations.
| Generation | Platform | Primary Software | Network Topology | Architecture Focus |
| Legacy Generation | PanelView Plus 1250 | FactoryTalk View ME | Linear / Star | Maintenance & Compatibility |
| Current Generation | PanelView Plus 7 Performance | FactoryTalk View Studio | DLR / Linear / Star | High Performance & High Availability |
Architectural Shift Summary:
- Software Ecosystem: The legacy 2711P-B12C15A1 utilizes FactoryTalk View Machine Edition, while the current Performance series (2711P-T7/T10/T12W/T15C22D9P) operates on the updated FactoryTalk View Studio environment.
- Hardware Evolution: The legacy architecture serves as a fixed-purpose HMI for existing infrastructure. The Performance series introduces a modular design philosophy, featuring higher-resolution displays, increased non-volatile memory (2 GB in Series B), and Windows 10 IoT Core integration for modern operational requirements.
- Lifecycle Context: The PanelView Plus 7 Performance terminals represent the active standard for current and future automation projects, whereas the PanelView Plus 1250 series remains available specifically for sustaining critical legacy plant infrastructure.
Technical Specifications
Heat Dissipation and Environmental Calculation
When selecting PanelView Plus 7 Performance terminals and designing control cabinet thermal management, refer to the following typical heat dissipation values (measured at 25 °C/77 °F):
- 6.5-in. models: 38...51 BTU (typical)
- 10.4-in. models: 48...51 BTU (typical)
- 12.1-in. models: 49...60 BTU (typical)
- 15-in. models: 61...71 BTU (typical)
Real-Time Clock (RTC) Backup
Terminals utilize an internal lithium battery to provide real-time clock and non-volatile memory backup.
- Battery Specification: CR2032 lithium coin cell
- Estimated Life: 4 years minimum at 25 °C (77 °F)
- Clock Accuracy: ±2 minutes per month
Software and Network Compatibility
| Product Series | Recommended Software Environment | Network Topology Support |
| PanelView Plus 7 Performance | FactoryTalk View Studio for Machine Edition, v2.6 or later | DLR, Linear, Star |
| PanelView Plus 1250 | FactoryTalk View Machine Edition (ME) | Standard Ethernet |
Important Notes:
- Operating System Distinction: Performance series Series A runs on Windows CE 6.0; Series B runs on Windows 10 IoT Core.
- Environmental Protection Integrity: Port plugs or covers must remain installed in all unused ports at all times to maintain the rated ingress protection (IP66) and corrosive atmosphere (K/BSHK series) standards.
Technical Compliance & Certifications
All Allen-Bradley PanelView HMI units in our inventory are manufactured to meet stringent global industrial standards, ensuring reliability and safety in demanding environments.
UL/cUL Compliance: Our PanelView 5000 and PanelView Plus units are UL listed (under UL 61010-2-201 and CSA C22.2 No. 61010-2-201), meeting rigorous electrical safety requirements.
CE Marking: All listed units comply with the European Union's CE directives for Electromagnetic Compatibility (EMC) and Low Voltage (LVD).
Hazardous Location Ratings: Many stock models are designed for Class I, Div 2 Groups A, B, C, and D operation (including ATEX/IECEx Zone 2 compliance for applicable configurations), providing protection in environments where flammable gases or vapors may be present.
RoHS Directive: Every unit complies with the Restriction of Hazardous Substances (RoHS) directive, meeting current environmental safety and substance limits.
RCM Certification: Our units carry the Regulatory Compliance Mark (RCM) for operation within the Australian and New Zealand markets, satisfying all relevant ACMA standards.
Compliance Note: Certification and compliance markings can vary based on specific product revisions and regional configurations. While the standards listed above apply to the PanelView 5000 and Plus product lines generally, please refer to the specific datasheet for your exact part number or contact our technical team for a copy of the Declaration of Conformity (DoC) for your specific unit.
Frequently Asked Questions (FAQ)
Q: Can the USB ports on the 2711P-T15C22D9P support industrial-grade external storage for continuous data logging?
A: Yes. The USB host ports support FAT32-formatted industrial USB flash drives for data logging. However, it is strongly recommended to use SLC (Single-Level Cell) flash-based drives to ensure long-term reliability against frequent read/write cycles and vibration in industrial environments.
Q: What is the maximum cable length allowed for the Ethernet connection on the 2711P-T10C22D9P to maintain stable performance?
A: The maximum distance between the terminal and the nearest network switch or another node is 100 meters (328 feet), as specified by IEEE 802.3 standards. Exceeding this distance requires the use of an industrial Ethernet repeater or fiber-optic conversion to prevent packet loss and communication timeouts.
Q: How does the display longevity of the 2711P-T7C22D9P compare to the legacy 2711P-B12C15A1?
A: The Performance series features an advanced LED backlight design with a rated half-life of approximately 50,000 hours at 40°C, providing a significantly longer operational lifespan compared to the CCFL (Cold Cathode Fluorescent Lamp) backlights typically found in the legacy 2711P-B12C15A1 units.
Q: Does the firmware of the Performance series support hot-swapping SD cards during runtime?
A: No. While the SD card slot is accessible, the operating system requires the card to be properly unmounted via the terminal's "Configuration Mode" menu before physical removal. Removing the card during an active read/write operation can result in file system corruption and potential loss of the running application project.
Inventory, Logistics & Ordering for 2711P-T15C22D9P
We stock the following PanelView terminal models (new, factory sealed):
- PanelView Plus 7 Performance Series: 2711P-T7C22D9P, 2711P-T10C22D9P, 2711P-T12W22D9P, 2711P-T15C22D9P
- PanelView Plus Legacy Series: 2711P-B12C15A1
All units include:
- Original Allen-Bradley packaging
- Clear product status report (date code, firmware version if available)
- 1-year warranty
Lead time: Same-day processing for in-stock items. Shipping via DHL, UPS, or FedEx.
Need help verifying firmware compatibility or safety certification requirements?
- Email: sales7@apterpower.com
- WhatsApp: +86 180 3017 5807
- Response time: < 2 hours during business hours (GMT+8)