Bently Nevada 330103-02-07-10-02-00 3300 XL 8 mm Probe

• Bently Nevada 330103-02-07-10-02-00 probe
• Unarmored 3300 XL 8 mm metric proximity probe
• M10 x 1 thread; 15 mm max engagement
• AA02: 20 mm unthreaded section
• BB07: 70 mm overall case length
• CC10: nominal 1.0 m total probe length
• DD02 ClickLoc; EE00 approval not required
Send Inquiry
Description

330103-02-07-10-02-00 Metric Proximity Probe

Bently Nevada 330103-02-07-10-02-00 is a 3300 XL 8 mm proximity probe with an M10 x 1 threaded case and an unarmored standard cable. Its AA02 and BB07 dimensions specify a 20 mm unthreaded section and a 70 mm overall case length.

The CC10 option provides a nominal 1.0 m total probe assembly length. DD02 selects a miniature coaxial ClickLoc connector, while EE00 indicates that agency approval was not required for this order.

20 / 70 mm Unthreaded / overall case lengths
1.0 m Nominal total probe length
EE00 Agency approval not required

20 mm Unthreaded Section and M10 x 1 Mounting

The metal probe case has two distinct dimensions: a 20 mm smooth section at the sensing end and a 70 mm overall case. The remaining case geometry includes the M10 x 1 threaded mounting portion.

330103-02-07 Case Dimensions
 
 
20 mm AA02 - Unthreaded length
70 mm BB07 - Overall case length
M10 x 1 · Maximum 15 mm Thread engagement limit

Simplified case relationship, not to scale. Refer to the manufacturer's dimensional drawing for installation.

Why the 15 mm Engagement Limit Matters

Bently Nevada specifies a maximum 15 mm engagement length for M10 x 1 probe threads. Longer engagement may cause binding during installation, even if the mounting hole uses the correct thread size.

The mounting holder must also provide the required insertion depth and adjustment travel so the probe tip can be positioned at the correct operating gap.

Mounting fit: A 70 mm overall case does not permit 70 mm of threaded engagement. Check the holder design, insertion depth and manufacturer's engagement limit before installation.

Bently Nevada 330103 series unarmored M10 x 1 proximity probe and ClickLoc cable, same 20 mm and 70 mm case geometry

330103 metric probe construction. The illustrated version is 330103-02-07-05-02-05, with a different probe length and approval option.

Unarmored Standard Cable

The 330103 family uses an unarmored probe lead. The DD02 connector option includes standard cable and a miniature coaxial ClickLoc connector.

External cable armor is not included in this configuration. The installed cable route should provide suitable protection against mechanical damage.

The M10 x 1 threaded case is shared with other metric probe configurations, but case length, cable length and approval suffixes can differ.

330103-02-07-10-02-00 Ordering Specifications

Order Code Field Selected Configuration
330103 Probe family 3300 XL 8 mm, M10 x 1 metric thread, without cable armor
AA = 02 Unthreaded length 20 mm
BB = 07 Overall case length 70 mm
CC = 10 Total probe length Nominal 1.0 m
DD = 02 Connector and cable Miniature coaxial ClickLoc connector, standard cable
EE = 00 Agency approval Not required

The manufacturer's 3300 XL 8 mm datasheet specifies the ordering dimensions and connector options. The probe's nominal assembly length is separate from its metal case length.

Bently Nevada 3300 XL 8 mm Proximity Transducer Datasheet

1.0 m Probe Versus the 0.5 m Related Version

The related 330103-02-07-05-02-05 has the same M10 x 1 case geometry and DD02 connector option. However, its total probe length is 0.5 m instead of 1.0 m, and its approval suffix is EE05.

Current Model 330103-02-07-10-02-00

Case: 20 mm / 70 mm

Probe length: Nominal 1.0 m

Approval option: EE00 - not required

Intended for the corresponding 1 m transducer system.

Related Variant 330103-02-07-05-02-05

Case: 20 mm / 70 mm

Probe length: Nominal 0.5 m

Approval option: EE05 - CSA, ATEX, IECEx

Requires review of the complete matched transducer-system length.

Why the 0.5 m Probe Is Not a Direct Drop-In

Although the two probes have the same metal case, their electrical lengths differ by 0.5 m. Installing the shorter probe without reviewing the extension cable and Proximitor combination can produce a mismatched system.

The approval difference also matters. EE00 does not select the same agency approval package as EE05. A replacement must satisfy the site's applicable approval requirements.

Same case, different system: Matching AA02 and BB07 confirms the nominal mechanical dimensions, not the complete electrical or approval configuration.

Matching the CC10 Probe with a 330180 Proximitor

CC10 specifies a nominal 1.0 m total probe assembly. The matching 1 m 3300 XL 8 mm transducer system uses a 330180 Proximitor Sensor. No extension cable is required for this nominal system length.

Matching 1.0 m Transducer Configuration
330103-02-07-10-02-00 Metric 8 mm probe Nominal total length: 1.0 m
→
330180 Proximitor 1 m system configuration Mounting and approval options selected separately

330180 option 10: panel mount. Option 11: DIN mount. Option 12: no mounting hardware.

The manufacturer lists a nominal DC resistance of 7.59 ± 0.50 ohms for a standard 1 m 3300 XL 8 mm probe, measured from the centre conductor to the outer conductor. This component value does not replace complete-system testing.

The Proximitor provides signal conditioning for the matched proximity transducer system. The probe itself is not an independent 4–20 mA transmitter.

EE00 Approval Selection and Cable Construction

EE00 Selected

Agency Approval Not Required

EE00 is the manufacturer's ordering choice where the listed agency approval package is not required.

EE05 separately selects CSA, ATEX and IECEx approvals. An EE00 probe must not be assumed suitable for a hazardous-area installation requiring certified equipment.

330103 / DD02

Standard Unarmored Cable

The 330103 has no metal cable armor. DD02 specifies a standard cable with miniature coaxial ClickLoc connector.

The 330104 is the corresponding armored metric probe family. Cable protection and mechanical routing must be considered before substitution.

DD01 is a different standard-cable option with a connector protector. The DD02 configuration does not select that protector option.

Approval boundary: EE00 does not establish compliance for a certified hazardous area. Required markings and approval documentation must be checked against the installation.

Installation and Replacement Identification

Before ordering or installing this probe, verify the mounting holder and the existing transducer system as a complete assembly.

Thread and Holder M10 x 1 thread, maximum 15 mm engagement and suitable adjustment.
Case Dimensions AA02 20 mm unthreaded section and BB07 70 mm overall case.
System Length CC10 nominal 1 m probe and matching 330180 configuration.
Connector and Cable DD02 ClickLoc connection with standard unarmored lead.
Approval Requirement EE00 ordering selection compared with the applicable site requirements.
Installed Equipment Existing Proximitor, monitor, target and required mounting arrangement.

After installation, qualified personnel should establish the operating probe gap and verify the monitoring response using the approved 3300 XL procedures.

330103-02-07-10-02-00 Frequently Asked Questions

What is the mounting difference between AA02 and BB07? +

AA02 describes the 20 mm smooth, unthreaded portion. BB07 describes the 70 mm overall metal case length. Both dimensions affect how the probe fits and adjusts within its mounting holder.

Why is M10 x 1 thread engagement limited to 15 mm? +

Bently Nevada specifies a 15 mm maximum engagement for M10 x 1 cases. Longer engagement may cause binding during installation. The mounting holder must also allow proper tip positioning and adjustment.

Can a BB17 case replace the shorter BB07 version? +

BB17 specifies a 170 mm overall case, compared with 70 mm for BB07. Direct substitution should not be assumed. The additional case length can affect mounting clearance, adjustment and mechanical fit.

Can the 0.5 m version directly replace this 1.0 m probe? +

Not without checking the complete transducer configuration. The 0.5 m and 1.0 m probes have different electrical lengths. The extension cable and Proximitor must be selected for the required total system length.

Is EE00 suitable when hazardous-area approval is required? +

EE00 means agency approval was not required in the selected order code. It should not be assumed to meet a hazardous-area certification requirement. Verify the correct approval option, equipment marking and certificate.

How does the unarmored 330103 differ from an armored 330104? +

Both families use metric M10 x 1 probe cases. The 330103 has an unarmored lead, while the 330104 includes external cable armor. Mounting dimensions, connector, total length and approvals must also be checked.

Which 330180 configuration matches this 1.0 m probe? +

Use a compatible 1 m 330180 Proximitor. The 10 mounting option is panel mount, 11 is DIN mount, and 12 has no mounting hardware. The agency approval field must be selected separately.

Related 3300 XL Probe Configurations

Related metric probes may share the same threaded case while differing in system length, cable armor or approvals. The complete ordering code determines the correct replacement.

Request 330103-02-07-10-02-00 Availability

Request the exact Bently Nevada 330103-02-07-10-02-00 configuration with a 70 mm metric case, nominal 1.0 m length and DD02 ClickLoc connector.

Include the required quantity, preferred condition and destination country. For replacement work, provide the existing probe label, mounting details and matching 330180 Proximitor model. Availability and commercial terms are confirmed with the quotation.

Request a 330103 Metric Probe Quote

Hot Tags: 330103-02-07-10-02-00, Bently Nevada 330103, 3300 XL 8 mm probe, M10 x 1 proximity probe, 70 mm probe case, 1 m proximity probe, 330180 Proximitor, 330103 metric proximity probe, 3300 XL 8 mm probe, M10 x 1 unarmored probe, 70 mm 3300 XL probe case, 330103 1 m probe replacement, 330103 20/70 mm metric probe

Hot Tags: 330103-02-07-10-02-00, Bently Nevada 330103, 3300 XL 8 mm probe, M10 x 1 proximity probe, 70 mm probe case, 1m proximity probe, 330180 Proximitor, vibration sensor, level sensor, gearbox monitoring, machinery health monitoring, asset lifecycle management, proximity sensor

Disclaimer:

PLCleader sells new and surplus products and develops channels for purchasing such products. This website has not been approved or recognized by any of the listed manufacturers or trademarks.

PLCleader is not an authorized distributor, dealer, or representative of the products displayed on this website. All product names, trademarks, brands, and logos used on this website are the property of their respective owners. The description, explanation, or sale of products with these names, trademarks, brands, and logos is for identification purposes only and is not intended to indicate any association with or authorization from any rights holder.