IS230SRLYH2A is a Simplex Relay Output terminal board developed by General Electric. The Simplex Relay Output terminal board is a simplex S-type board that accepts a PDOA/YDOA I/O pack and provides 12 form C relay output circuits via 48 customer terminals. SRLY is physically the same size, has the same customer terminal locations, and uses the same I/O pack mounting as other S-type terminal boards. There will be no components higher than an attached PDOA / YDOA I/O pack, allowing for terminal board double stacking. As position feedback to PDOA / YDOA, each SRLY relay employs an isolated contact pair.

IS230SRLYH2A Characteristics

Max response time on - 25 ms typical
Max response time off - 25 ms typical
Contact material - Silver cad-oxide
Contact life - Electrical operations: 100,000, Mechanical operations: 10,000,000
Fault detection - Relay position feedback using contact pair separate from load contacts
Technology- Surface-mount.
Temperature Operating- -30 to 65 degrees Celcius
Humidity Operating is 5 to 95% non-condensing
Cooling- Free air convection
IS230SRLYH2A Diagnostics
- The I/O pack interrogates the terminal board connectors' own ID device.
- The ID device is a read-only chip that contains the serial number, board type, revision number, and plug location of the terminal board.
- A hardware incompatibility fault is generated when the chip is read by PDOA or YDOA and a mismatch is encountered.
- Each option board includes an ID device that uniquely identifies the board. By monitoring an isolated set of contacts on each relay, the SRLY provides diagnostic feedback to PDOA or YDOA indicating each relay position.
- When WROB is used in conjunction with SRLY, isolated voltage feedback is used to detect fuse status for the board's six fuse pairs. Isolated voltage feedback is used to monitor each fuse when WROF is used with SRLY. A diagnostic alarm is generated if voltage is present and the fuse is open. To use the feedback circuit without the fuse, disable this alarm in the ToolboxST PDOA / YDOA configuration.
- Isolated voltage feedback is used to monitor each fuse when WROG is used in conjunction with SRLY. A diagnostic alarm is generated if voltage is present and the fuse is open.
keywords: is230srlyh2a;is200srlyh2aaa;GE IS230SRLYH2A;IS200SRLYH2AAA pdf;IS230SRLYH2A datasheet;IS200SRLYH2AAA manual;IS200SRLYH2AAA GE
hot-sale product
| ABB | CMA131 3DDE300411 | BENTLY NEVADA | 330703-000-040-10-02-00 |
| ABB | CMA133 3DDE300413 | BENTLY NEVADA | 330703-000-040-10-11-00 |
| ABB | CMA135 3DDE300411 | BENTLY NEVADA | 330703-000-060-10-02-00 |
| ABB | CMA136 3DDE300416 | BENTLY NEVADA | 330703-000-060-10-02-00 |
| ABB | CMA137 3DDE300417 | BENTLY NEVADA | 330703-000-060-10-02-CN |
| ABB | CMA35 GVT3605799 | BENTLY NEVADA | 330703-000-060-50-12-00 |
| Schneider | 140CPU65160S | HONEYWELL | MC-TAIH04 51305900-175 |
| Schneider | 140CPU67060 | HONEYWELL | MC-TAIH12 51304337-150 |
| Schneider | 140CRA21220 | HONEYWELL | MC-TAIH12 51304337-150 |
| Schneider | 140CRA93100 | HONEYWELL | MC-TAIH14 51305887-150 |
| Schneider | 140CRP93100 | HONEYWELL | MC-TAMR03 51309218-175 |
| Schneider | 140CRP93200C | HONEYWELL | MC-TAMR04 51305907-175 |
| Schneider | 140DAI74000 | HONEYWELL | MC-TAMT03 51309223-175 |
Is GE IS230SRLYH2A IS200SRLYH2AAA not the part you are wanting?
Check out the rest of our website to see what else we have to offer!
Urgent contact:Vicky
Email→sales7@apterpower.com
Call or Whatsapp→+8618030175807