Specifications
- Type: Digital I/O Module
- Model: UR6AV
- Input/Output Channels:
- Digital Inputs: 6 configurable inputs
- Digital Outputs: 6 configurable outputs
- Input Voltage Range: 24V DC nominal, with flexibility for various industrial power standards
- Output Voltage Range: 24V DC for relay control
- Communication Protocol: Modbus RTU, DNP3, and IEC 61850 for integration with supervisory control and data acquisition (SCADA) systems

About the UR-6AV

General Electric Multilin's UR-6AV is a Digital I/O module that provides digital input/output contacts to the UR series. Users should consider purchasing this model if system needs expand and/or their Universal Relay did not originally come with the digital I/O feature (denoted by the "XX" in its model number). Additionally, this module can function as a replacement or upgrade for users struggling with their current module.
This version of the module contains both Form-A and Form-C outputs. Form-A digital outputs are typically open contacts with one normally open terminal (NO) and one common terminal (C). The terminals are isolated from signal ground. Form-C digital outputs, on the other hand, are switching or "changeover" contacts that contain one normally open terminal (NO), one common terminal (C), and one normally closed terminal (NC). These terminals are also isolated from signal ground, like its Form-A counterpart.
The relay's FlexLogic technology assists in determining how the system receives digital and analog inputs that are used to produce digital and analog outputs. FlexLogic is unique to General Electric Multilin and is a highly configurable programming logic that increases the general versatility of the system. Users can execute up to 1024 lines of code that highly specify relay functionality.
Frequently Asked Questions about UR-6AV
What is different about a UR-6AV Multilin digital I/O module found in a UR series universal relay system?
The UR-6AV Multilin digital I/O module is unique to other modules and order options because it actually contains two different types of I/O cards. The 6A order code affords the digital I/O module with two Form-A outputs that have voltage and optional current monitoring, and two Form-C outputs. In addition, the unit has 8 digital inputs. Form-A outputs are ideal when fast activation speeds are necessary in either wet or dry contact options. The Form-A outputs have activation speeds that are less than 4ms. Form-A outputs (and SSR outputs) are beneficial to the end user because they can come with optional circuit detection if needed. The UR-6AV does have the optional current monitoring feature. This particular digital I/O module does not have a mechanically latching configuration, but in the event that this order code is selected it can help eliminate the need for a lockout relay. The order code with the most variability is the 6V option order code for a Multilin digital I/O module. This order specification includes 2 Form-A outputs, with optional voltage monitoring, a Form-C output, two outputs that have latching features, and eight digital inputs.
Related words:UR6AV;GE Multilin UR6AV;UR6AV pdf;UR6AV datasheet;UR6AV manual;UR6AV sell;UR6AV new;UR6AV GE
Select PLC Leader
- Source hard-to-find and obsolete industrial automation parts globally.
- Benefit from fast shipping options: Choose from UPS, FedEx Priority Overnight, DHL, and more.
- Receive international shipments: We ship worldwide via DHL, FedEx, and UPS.
- Leverage over 20 years of automation expertise (nearly half a century).
- Find your ideal replacement or repair solution with our in-depth knowledge.
Is GE Multilin UR6AV not the part you are wanting?
Check out the rest of our website to see what else we have to offer!
Contact Us-For Any Further Questions
| Manager | Cell Phone/Whatsapp | |
| Vicky | sales7@apterpower.com | +8618030175807 |