The HIMA HIMatrix F35 Safety-Related Controller is a compact, high-performance controller designed for safety-critical applications in industrial automation. It offers advanced safety functions and reliable performance, adhering to the highest safety standards, such as SIL 3 (IEC 61508/61511). The HIMatrix F35 ensures safe operation in industries like oil and gas, power generation, chemical processing, and more, where functional safety is paramount. Its modular design, flexible configuration, and robust diagnostics make it an ideal choice for modern safety systems.

⇒ Contact Us: sales7@apterpower.com // Whatsapp: +8618030175807 // Skype: live:2435aba439730baa
Key Parameters and Specifications

Processor:High-speed processor for real-time safety control.
Digital Inputs: 24 (safety-related, SIL 3 certified).
Digital Outputs: 16 (safety-related, SIL 3 certified).
Analog Inputs: 4 (configurable for various signal ranges).
Communication Protocols:upports Ethernet-based protocols like Modbus TCP, PROFINET, and PROFIsafe.
Safety Certification:SIL 3 certified according to IEC 61508 and IEC 61511.
Power Supply:24 VDC nominal input voltage.
Operating Temperature:-25°C to +60°C for versatile industrial environments.
Housing and Mounting:DIN rail mountable, compact form factor.
Diagnostic Features:Integrated system diagnostics with fault indicators.
Memory:Non-volatile memory for storing safety programs and configuration.
Supply Voltage Monitoring
The HIMatrix system is a single voltage system. In accordance with IEC/EN 61131-2, therequired supply voltage is defined as follows:
| Supply voltage | |
| Nominal value | 24 VDC, -15...+20 % |
| 20.4...28.8 V | |
| Max. permissible function limits incontinuous operation | 18.5...30.2 V(including ripple) |
| Maximum peak value | 35 V for 0.1 s |
| Permissible ripple | r < 5 % as r.m.s. value |
| rPP < 15 % as value peak-to-peak | |
| Ground | L- (negative pole) |
| Earthing the ground is permitted, see Chapter7.2.5.1. |
Frequently Asked Questions (FAQs)
Q1: What industries commonly use the HIMA HIMatrix F35?
A: The F35 is widely used in oil and gas, chemical processing, power generation, transportation, and machine safety applications due to its high safety integrity level and flexible configuration.
Q2: Can the HIMatrix F35 operate in harsh environments?
A: Yes, the F35 is designed to withstand temperatures from -25°C to +60°C and operates reliably in challenging industrial conditions.
Q3: How does the HIMatrix F35 achieve SIL 3 certification?
A: The F35 complies with IEC 61508 and IEC 61511 standards, undergoing rigorous testing to ensure it meets SIL 3 safety integrity requirements.
Q4: Is the HIMatrix F35 compatible with other safety systems?
A: Yes, it supports communication protocols like Modbus TCP, PROFINET, and PROFIsafe, making it compatible with a variety of industrial safety and control systems.
keywords: hima himatrix f35;himatrix f35;HIMA HIMatrix F35;HIMatrix F35 pdf;HIMatrix F35 datasheet;manual HIMatrix F35
Hot-Sale Product
| Bently Nevada | Emerson | Siemens | Schneider |
| 330180-51-05 | KJ4010X1-BF1 12P0831X062 | 6DD1611-0AD0 | 140CPU65150C |
| 330180-51-CN | KJ4010X1-BF1 12P0831X072 | 6DD1660-0AE0 | 140CPU65160S |
| 330180-90-00 | KJ4010X1-BG1 12P0830X062 | 6DD1681-0AE2 | 140CPU67060 |
| 330180-90-05 | KJ4010X1-BG1 12P0830X072 | 6DD1681-0AG2 | 140CRA21220 |
| 330180-90-CN | KJ3001X1-BG1 12P0557X162 | 6DD1681-0AJ1 | 140NOE77110 |
| 330180-91-00 | KJ3002X1-BD1 12P1033X102 | 6DD1611-0AD0 | 140NOM21200 |
| 330190-040-01-CN | KJ3002X1-BF1 12P1732X082 | 6DD1660-0AE0 | 140XCP50000 |
| 330190-045-01-CN | KJ3002X1-BG2 12P1731X082 | 6DD1681-0AE2 | 140XCP51000 |
| 330190-080-01-00 | KJ3008X1-BA1 12P2293X052 | 6DD1681-0AG2 | 490NRP95400 |
| 330193-00-05-10-00 | KJ3102X1-BA1 12P1863X032 | 6DD1681-0AJ1 | 990XCP98000 |
Is HIMA HIMatrix F35 not the part you are wanting?
Check out the rest of our website to see what else we have to offer!
Waiting for your inquiry--Send To sales7@apterpower.com