Honeywell FC-IOTA-R24 Safety Manager IO Termination Assembly
The Backplane can operate with the Honeywell Remote Universal Safe IO devicetype SM-RUSIO DCS system via the Redundant IOTA board (FC-IOTA-R24).The SM-RUSIO module has 32 universal safe IO channels with configurable channelfunction; configuration is done via the Honeywell software configuration toolSafety Builder.Each channel on the SM-RUSIO DCS system can be configured as: Digital Input (DI),Digital Output (DO), Analog Input (AI) or Analog Output (AO).
Whatsapp/mobile phone

Product Details

The FC-IOTA-R24 can be used in applications up to SIL 3, in compliance with IEC 61508/61511.The FC-IOTA-R24 provides for Connectors for two (redundant) RUSIO-3224 or RUSLS-3224 modules:
- 32 (universal) IO channel connections (CN1 and CN2)
- 4 (identical) V+ connections (CN3), for active AI devices
- Two RJ45 connectors for 100MB Ethernet communication (RIOLA and RIOLB)
- 24V power connection
The RUSIO-3224 or RUSLS-3224 modules are placed on the indicated positions of the IOTA-R24. See forFigure 1 details.
The FC-IOTA-R24 module has two switches:
- Use POWER 1 to switch Module 'A' on and off
- Use POWER 2 to switch Module 'B' on and off
The node number of the IOTA-R24 is set by placing the proper node addres jumper on the IOTA-R24 assembly.The Emergency ShutDown (ESD) function can be enabled or disabled with the ESD (CH32) link.The IO field signals are connected on CN1 and CN2; see Figure 1. The minus-row of CN1 and CN2 (leftside) are all connected with 0V. The plus-row of CN1 and CN2 (right side) are the 'real' channels. Any typeof IO field signal has only to be connected to the two connections of the applicable universal channel.
Description
Model: FC-IOTA-R24
Type: I/O Termination Assembly (IOTA)
Voltage: 24V DC
Connection Type: Modular terminal blocks for I/O signals
Mounting: DIN Rail/Panel mountable
Compatibility: Honeywell Safety Manager controllers
The Honeywell FC-IOTA-R24 is an I/O termination assembly (IOTA) designed for seamless integration with Honeywell's Safety Manager. This termination unit supports various input/output connections, providing a reliable interface between field devices and the safety system. The FC-IOTA-R24 ensures safe and efficient operation, enabling critical process control and safety functions in hazardous environments.
Your Automation Parts Partner
Honeywell's DCS system mainly includes:
TDC 2000,TDC3000,TPS,Experion PKS ( C200 , C300 ),FSC
Honeywell SYSTEM CONFIGURATION
1.Control Processor
2.Fault Tolerant Ethernet Bridge ( FTEB )
3.Controlnet Interface ( CNI )
4.Redundancy Module ( RM )
5.IOLIM ( I/O Link Interface Module )
6.PM I/O
7.FTA Board
For more information on the FC-IIOTA-R24 manual, please contact us
- Rapid Shipment: In-stock items ship within 1-3 days.
- Industry Expertise: Over a decade of sales experience.
- Extensive Inventory: Wide range of brands and global warehousing.
- Quality Assurance: Verified products with a 1-year warranty.
Is honeywell FC IOTA R24 not the part you are wanting?
Check out the rest of our website to see what else we have to offer!
Contact us immediately for a good price
Email: sales7@apterpower.com
Whatsapp: +8618030175807
Hot Tags: honeywell fc-iota-r24 safety manager io termination assembly, honeywell fc-iota-r24 safety manager io termination assembly manufacturers, suppliers, check valves, dryers, pallet racks, oem services, inventory management, software design