Products Description
The Woodward 9907-028 9907-029 Synchronizer Control is a high-precision engine synchronization system designed for critical power generation and industrial applications. It supports a speed range of 0–40,000 RPM with an accuracy of ±0.1% of reading, ensuring precise alignment of generator or engine speeds. Equipped with two independent input channels for magnetic or VRS sensors, the unit provides output signals via 4–20 mA and RS-485 Modbus for seamless integration into control networks. With a rapid response time of less than 2 ms for a 90% step change, and SIL 3 certification to IEC 61508, it meets stringent safety requirements. Built for harsh environments, the 9907-028 9907-029 offers vibration resistance up to 20 g (IEC 60068-2-6) and operates reliably between –40 °C and +85 °C.The 9907‑028 9907-029 is widely used in industrial power generation installations, utility interconnections, and multi‑genset power systems where smooth, reliable synchronization is required.
Technical specifications
Model: 9907-028 9907-029
Type: Speed & Phase Matching Synchronizer (SPM‑A)
Input Voltage: 115 V / 230 V AC RMS ±10 %
Frequency: 50 Hz / 60 Hz
Phase Angle Window: ±10 degrees
Voltage Matching: Not included (speed/phase only)
Voltage Tolerance: ±10 %
Power Consumption: ≤ 5 W
Operating Temperature: –45 °C to +70 °C
Optimal Operating Temperature: +10 °C to +30 °C
Modes: OFF, RUN, CHECK, PERMISSIVE (via external switch)
Outputs: Relay outputs for breaker close and synchronizer control signals (high/low impedance or EPG selectable)
Speed Range: 0-40,000 RPM
Accuracy: ±0.1% of reading
Input Channels: 2 independent (magnetic/VRS)
Hot Tags: 9907 028; Woodward 9907-028; 9907-028 pdf; 9907-028 datasheet; 9907-028 manual; 9907-028 sell; 9907-028 new; 9907-028 Woodward
Frequently Asked Questions (FAQ)
Q1: What role does the Woodward 9907-028 9907-029 play in a power generation setup?
A1: The 9907-028 acts as an automated synchronizer, precisely matching the output of an incoming generator to the live bus bars to facilitate a safe, disturbance-free parallel connection.
Q2: What are the acceptable voltage input limits for the 9907-028 unit?
A2: This specific 9907-028 hardware is rated to monitor and process alternating current (AC) line-to-line voltages anywhere between a minimum of 80V and a maximum of 300V.
Q3: Is the 9907-028 9907-029 compatible with different types of control power sources?
A3: Yes, the 9907-028 provides flexible installation options by supporting power from a 24V DC battery system or via selectable 115V/230V AC mains.
Q4: In what way does the 9907-028 trigger the actual breaker closure?
A4: The 9907-028 uses heavy-duty internal relay logic to complete the closing circuit of the breaker only after the synchronization window has been successfully achieved.
Q5: How does the 9907-028 protect the system from the risks of poor synchronization?
A5: To prevent mechanical and electrical damage, the 9907-028 real-time analyzes the frequency, voltage magnitude, and phase relationship, blocking any closure attempt until the two sources are in perfect alignment.
Is Woodward 9907-028 9907-029 not the part you are wanting?
Check out the rest of our website to see what else we have to offer!
Key Features and Benefits
- Automated Grid Synchronization:The 9907-028 9907-029 serves as a high-precision bridge between a standby generator and the utility bus, continuously monitoring phase angles and frequency offsets to ensure a perfect electrical match before connection.
- Intelligent Breaker Management:Once the synchronization window is perfectly aligned, the 9907-028 executes a rapid closure command, eliminating the risk of "out-of-phase" paralleling that can cause catastrophic mechanical stress to the prime mover.
- Versatile Logic Modes:Engineers can toggle the 9907-028 9907-029 between specialized modes like "Permissive" and "Check," allowing the unit to act as either a primary automatic synchronizer or a secondary safety monitor for manual operations.
- Global Power Grid Flexibility:Designed to handle a variety of international standards, the 9907-028 supports both 115V and 230V AC configurations, making it a "go-to" component for global industrial power projects.
- Hardened Electrical Protection:Built to withstand the electrical noise and thermal spikes found in heavy-duty switchgear cabinets, the 9907-028 9907-029 maintains its timing accuracy even in the most demanding industrial environments.
Recommended products
| DS150 | DMP8 | PM+3000C TS MM-PMD24T0C |
| N2930675 | 856282835-16 | A06B-0272-B605#S000 |
| 106801-CS07 | Allen-Bradley 1609-U500E/A | 8721ASA005XA2N0AHQ4Q8 |
| MAC093C-0-FS-3-C/110-B-2/S001 | 1-604-0245 2150RPM | SN514005024004 |
| 5ZBZCH40300ZM0-001 | MPP1428Q6S-KPSV | 223F 533 117-20 |
| CBB2HLTS34C | W0760060LSAS03DHMDK | T025T621SCAUEZZZZ |
| R036050000 | 6033-3076 | QS0350-U06STACW |
| RT81024LF082C | AX4022T-EB-P3-S | SLLP23-1540P88 |
| 5W4C1H-MDH4/04 | Valenite Vgage 407-500W | 60AS04-SVW00A20A1B |
| Fisher 1061-8500 | Kop-flex 254 KD 21 | 0811404843 |
| 1061-8500 | CRK8-30 U-W-A-AUUV Model B42Z98103 | EL3100R |
| MPM692BSG6H1N | MXM-5433CFVH | F7-A4K6G7 |
| 828-0212-2R C4G7-24X-E00 | COGNEX 828-0290-1R | SP1255/SLG060-100-XXXS-EM2-1B8-10-SS-XH-69691 |
| 30-4 AR-PV/V/C-F-31U7U7BG | MHD090B-035-NG0-UN R911277757 | MPCKT22NAX20N |
| AX4022T-EB-P3 | 5W4C80-FEC8/0 | P1794915-0104 |
Connect with Us & Request a Quote
--->Manager: Vicky
--->Email: sales7@apterpower.com
--->Call or Whatsapp: +86 18030175807