Products Description
The Schneider Electric Square D D8430 Phase Failure Relay is an industrial protection device designed to monitor three-phase power systems and ensure safe operation of electrical equipment.This phase failure relay operates with an operating voltage of 240 V AC and supports AC input ranges of 230 V and 460 V. It works at a standard frequency of 50/60 Hz, making it suitable for a wide range of industrial power systems. The device is designed to respond quickly, with a tripping time of less than 2 seconds to ensure rapid system protection.The relay features SPDT contact configuration with both NC and NO outputs, providing flexible integration into control and alarm circuits. It is built using terminal block connections for secure and reliable wiring in industrial panels.Rated for up to 10 A at 240 V AC, the relay is designed for long-term durability with a mechanical life cycle exceeding 10 million switching operations. It also supports Class I, II, and III protection categories, ensuring compatibility with different levels of industrial safety requirements.With its fast response protection, durable switching performance, and robust industrial design, the Square D D8430 Phase Failure Relay is well suited for motor protection systems, industrial power distribution panels, and automation applications requiring reliable three-phase monitoring and safety control.
Product Specifications & Standards

Model: D8430
Product Type: Phase Failure / Phase Monitoring Relay
Response Time: < 2 seconds
Relay Output: SPDT (Form C), NO/NC
Hazardous Ratings: Class I, II, III (Div 1/2)
Wiring: Plug-in Terminal Block
Rated Voltage: 230 / 460 V AC (50/60 Hz)
Operating Ambient Temperature: -40°C to +70°C
Enclosure Rating: IP20
Operating Voltage: 240V AC
Operating Frequency: 50/60 Hz
Current Rating: 10 A @ 240V AC
Relay Life Cycle: Over 10 million cycles
Nominal Voltage Range: Typically up to 480 VAC
Undervoltage Adjustment Range: Approximately 75% to 100% of nominal voltage
Phase Unbalance Detection: Around 10% threshold typical
Primary Usage Scenarios
- Motor Protection Systems---In high-demand Motor protection systems, the D8430 acts as a critical safeguard against the "silent killers" of industrial motors: phase loss and voltage imbalance.
- Industrial Pump Control Panels---For Industrial pump control panels, the integration of the D8430 ensures that pumps do not operate under damaging phase-reversal conditions.
- HVAC and Compressor Systems---Within large-scale HVAC and compressor systems, the D8430 provides an essential layer of reliability for high-value chilling units and air compressors.
- Conveyor and Production Line Machinery---The D8430 is a staple in Conveyor and production line machinery, where synchronized movement is paramount.
- Electrical Protection for Rotating Equipment---Specifically engineered for Electrical protection for rotating equipment, the hardware's solid-state detection handles the high-vibration environments typical of fans, blowers, and centrifuges.
Is Square D D8430 not the part you are wanting?
Check out the rest of our website to see what else we have to offer!
The Competitive Edge
- Advanced Power Quality Monitoring:The D8430 is a precision phase failure relay designed to provide real-time monitoring of three-phase power systems.
- Comprehensive Fault Detection:Engineered for versatility, the D8430 is capable of detecting a wide array of power issues, including phase loss, phase reversal, undervoltage, and significant voltage imbalances.
- Critical Motor and Hardware Protection:By implementing the D8430, operators can effectively prevent motor overheating and catastrophic mechanical damage caused by abnormal voltage conditions.
- Industry-Standard Compliance:Reflecting the legacy of Square D and Schneider Electric engineering, the hardware is designed to meet the stringent electrical standards required for global manufacturing and power distribution facilities.
- Flexible and User-Defined Thresholds:The D8430 features adjustable voltage and imbalance setpoints, allowing for customized protection profiles tailored to specific site conditions.
- Optimized System Safety:The module serves as a proactive safety component, triggering immediate shutdowns or alarms when phase sequences are reversed, thereby protecting rotating machinery from running in the wrong direction and causing process errors.
Manager: Vicky►Email: sales7@apterpower.com►Call or Whatsapp: +8618030175807
Recommended products
| 1700R13DBZEZZZ | EC02LA10-3 | 920-600-9 |
| MZEU25-E1 | ABB DSQC 266B 3HAB8797-1 | A06B-0223-B100 |
| BM20MM-C,Q1Q1VMG PN P006795 DN/20-E2 | 1195S010P1S0800CG2 | SGK2025 |
| 41114-1 | VTS205 | s05b1s2tans700 |
| EE100-00003 | A92 8572 | 07589-30 |
| GG20025B01M02 | 900C30-0360-00 | 9407-701-00001 8547 |
| PVS-1B-16R2S4-U-12 SS-G01-A3Z-R-D2-31 | Yokogawa YF108-AAUB1A-S3S3*E/FMF | 3008 175L1072 |
| 55223 | DN50 | 1960384 |
| D8K D8L D9L 1990234 | 3051CG4A22A1AE5M5S1B4Q4Q8Q16 300PSI | 34.0580 400/10M RBA FA2012 4431 |
| LC-80 | 1-018-52-056-1 | VS-050S-MF1 |
| 2711P-K6M20A8 | FR-A840-0.75K-1 | CSH01.3C-ET-ENS-EN1-CCD-NN-S-NN-FW R911331131 |
| NA93800-20024 | EUA08895 N6711149 | Allen-Bradley 2711-K5A1 /H |
| 1130T10-B | QBFD-M016 | 39MV07-2-CC-T-SS-BN-MB-LF |
| 1-080-52-357-0 | R454970356 | 6252AKH01-NS |
| 8351A-T-01 | 751-901 | CJT70-FA80B190B-DAB |
Hot Tags: d8430; Square D D8430; D8430 pdf; D8430 datasheet; D8430 manual; D8430 sell; D8430 new; D8430 Square D