Allen Bradley/Rockwell 1756-OF6CI/A ControlLogix 6 Pt Isolated Module

Manufacturer: Allen Bradley/Rockwell
Part Number: 1756-OF6CI/A
Origin: USA
Condition: brand new
Delivery Time: 3-5 days
HS Code: 8537101190
Shipping Weight: 0.28kg
Payment Term: 100% bank transfer in advance
Technical documents, COO certificate support
Send Inquiry
Description

Product Description

The Allen-Bradley 1756-OF6CI/A module is a ControlLogix Series A general purpose isolated analog current/voltage output module. This module has 6 available individually-isolated current outputs. It also has a 13-bit resolution across 21 milliamps (2.7 µA). It requires either the 1756-TBNH or 1756-TBSH removable terminal block housing (RTB) before it can be installed in a grounded and installed chassis.

Communication format types available with the 1756-OF6CI module are the integer and floating point formats. Features of this analog output module include data echo, ramping/rate limiting, clamping/limiting, clamp/limit alarms, and hold for initialization. The programs the 1756-OF6CI's features.

1756-OF6CI-A

Technical specifications for 1756-OF6CI/A

 

Manufacturer Allen-Bradley / Rockwell Automation
Series ControlLogix
Part Number 1756-OF6CI/A
Product Type Analog Output Module
Available Current Range 0 to 21 mA
Resolution 2.7 uA
RIUP Yes
Module Fault Reporting Yes
Status Indicator Yes
Software RSLogix 5000

 

Description

 

1756-OF6CI-A new

The Allen Bradley 1756-OF6CI/A 8-Point Analog DC Output Module is a current loop Analog DC 8-point output module in the controlLogix family of high speed I/O modules, which provides shared high-speed output signals between multiple ControlLogix Controllers. This module is installed on the Controller chassis and requires a removable terminal block or a fused interface module (IFM) for installation and all field-side wiring. The 1756-OF6CI has 6 individually isolated 13-bits outputs, with 0 to 21 milliAmpere low signal and high signal user count outputs. This module draws 250 milli-Ampere chassis current at 5.1 Volt DC and 225 milli-Ampere currents at 24 volt DC, and it has a total backplane power of 6.7 Watts at 0 to 550 Ohms load and 8.5 Watts backplane power a 551 to 1000 Ohms load. The 1756-OF6CI unlike most 1756 I/O modules do not have open circuit detection capability, but it provides 24 Volt DC overvoltage protection and also provides short-circuit protection by electronically limiting the output current to 21 milli-Ampere or less. This module requires field calibration once every 6 months of use, and it can be calibrated to an accuracy of 0.01% over 4 to 21 milli-Ampere operating range.

It has maximum offset drift of 1 micro-Ampere per degree Celsius, with a maximum gain drift of 100ppm per degree Celsius, and this module produces a high-speed output signal with less than 0.6% module error. It has a maximum scan time of 25 milliseconds for floating point data format, and 10 milliseconds for integer data format, and it provides easy conversion between data format via R-Ladder DAC converter. The 1756-OF6CI has 250 Volt isolation voltage between the output channel to the backplane, using basic insulation tested at 1350 volt AC for 2 seconds. It is electronically keyed to the chassis via digital control to ensure precision, and it is keyed to the removable terminal block (RTB) via mechanical mode. It is designated T4A North America, and T4 IEC rated temperature code, and it has a functioning temperature limit of 0 to 60 degree Celsius (32 to 140 degree Fahrenheit) at non-condensing 5% to 95% relative humidity range. The 1756-OF6CI has no rated enclosure, and it is UL, CSA, CE, EX, C-TICK, FM, and KC certified.

 

FAQs

 

Q1: How do I configure the 1756-OF6CI/A module?

A1: Use RSLogix 5000 or Studio 5000 software to configure the module. Ensure you set the correct output range and scaling for your application.

 

Q2: What type of diagnostics does the module provide?

A2: The module supports real-time fault detection, such as open-wire, overcurrent, and output status.

 

Q3: Can the module operate in hazardous environments?

A3: Yes, it is certified for use in Class I, Division 2 and ATEX Zone 2 environments.

 

Q4: Is the module compatible with older ControlLogix chassis?

A4: Yes, as long as the chassis and firmware versions support the module.

 

keywords:1756 of6ci a;Allen Bradley 1756-OF6CI-A;1756-OF6CI-A pdf;1756-OF6CI-A datasheet;manual 1756-OF6CI-A;1756-OF6CI-A new

 

Complete Service We Offer

 

  • Swift & Secure Delivery:Your order shipped within 1-2 business days via DHL, UPS, FedEx, or your preferred carrier.
  • Global Reach:Serving customers worldwide with efficient and reliable international shipping.
  • Reliable Payment Options:Convenient and secure T/T (Telegraphic Transfer) payment options for your convenience.
  • Dedicated Customer Support:24/7 after-sales service available to assist with any inquiries or concerns.Our experienced support team provides prompt and professional assistance.We are committed to ensuring your complete satisfaction.

 

 

Is Allen Bradley/Rockwell 1756-OF6CI/A not the part you are wanting?

Check out the rest of our website to see what else we have to offer!

 

 

Contact a sales manager for the best price and lead time.

 

Sales manager: Vicky  //  Email: sales7@apterpower.com

Whatsapp: +8618030175807 (Cell Phone)  //  Skype: live:2435aba439730baa

 

Disclaimer:

PLCleader sells new and surplus products and develops channels for purchasing such products. This website has not been approved or recognized by any of the listed manufacturers or trademarks.

PLCleader is not an authorized distributor, dealer, or representative of the products displayed on this website. All product names, trademarks, brands, and logos used on this website are the property of their respective owners. The description, explanation, or sale of products with these names, trademarks, brands, and logos is for identification purposes only and is not intended to indicate any association with or authorization from any rights holder.