The 1734-IB8S is an Allen-Bradley manufactured module used in applications with Safety Instrumentation Level (SIL) requirements. This module is a POINT Guard IO Safety module with Eight (8) Current Sinking Input Channel and Four (4) pulse Current Sourcing Pulse Test Outputs.
This module is typically used in applications that perform safety applications such as Emergency Stop Push Button, Gate Switches, Light Curtains and other safety devices may be connected to this module. It features a channel with Dual-channel mode capability for evaluating consistency of Two (2) input signals which enables the module to be used in applications that with Safety Category 3 and 4.
Technical Specifications for 1734-IB8S
| Manufacturer | Rockwell Automation |
| Brand | Allen-Bradley |
| Part Number/Catalog No. | 1734-IB8S |
| Series | POINT I/O |
| Module Type | Guard I/O Safety Module |
| Input Type | Current Sinking |
| Enclosure Type | Open |
| Number of Inputs | Eight (8) Inputs |
| No. of Pulse Test Outputs | Four (4) Pulse Test Outputs |
| Operating Supply Voltage | 24 Volts DC (nom) |
| Available Series | A and B |
| Weight | 2.2 ounces |
About 1734-IB8S

The 1734-IB8S is a POINT Guard I/O safety Discrete Input Module. This module is used with the POINT I/O product family for implementing Common Industrial Protocol (CIP) safety protocol extension implemented over Ethernet I/P and DeviceNet communication protocol. Through these protocol and connections, safety messages can be transferred. It is not compatible with 1734-ADN, 1734-ADNX, 1734-APB, and 1734-ACNR communication adapters. This module features Eight (8) Current Sinking inputs with a ON state input of 11-30V at 3.5 mA DC and reaction time of less than 16.2 ms. It also has Four (4) Current Sourcing Pulse Test Outputs with T0, T1M, T2 and T3M output sources. This safety module is available in series A and Series B. With Series A, the module consumes current of 175 mA while Series B has current consumption of 110 mA. Series A tends to dissipate more heat thus, it is recommended to use termination modules particularly 1734-CTM or the Common Terminal Module. Series B modules are designed with less heat dissipation thus CTM modules are not recommended unless required by the control system design. Series B module cannot be used to replace a Series A module in a plug and play manner. Similarly, a Series A module cannot do the same plug and play replacement. EDS files must be loaded to these module to be recognized in the network. The 1734-IB8S features compatibility with safety devices such as gate switches, Emergency Stop Pushbuttons, light curtains and similar devices. It has Single channel mode that is used to evaluate an input signal per channel, allowing the module to be used in Safety Category 2 and in applications rated up to including performance Level d / SIL CL2. In this mode, the channelÕs Point Mode configuration is set to Safety Pulse Test. It also has Dual channel mode used for evaluation of consistency between Two (2) channels.
1734-IB8S Digital Input Module Features
• Safety digital inputs
– Safety devices, such as an Emergency Stop Push Button, gate switches,and safety light curtains, can be connected.
– Dual-channel mode evaluates consistency between two input signals(channels), which allows use of the module for safety Category 3 and 4and in applications that are rated up to and including PLe/SIL CL3when both channels' Point Mode configurations are set to Safety PulseTest.
– Single-channel mode evaluates one input signal (channel), which allowsuse of the module for safety Category 2 and in applications that arerated up to and including PLd/SIL CL2 when the channel's PointMode configuration is set to Safety Pulse Test.
– You can configure a discrepancy time to control how long two channelsare allowed to be discrepant before a fault is declared.
– It is possible to perform an external wiring short circuit check wheninputs are wired in combination with test outputs. The module must bewired in combination with test outputs when this function is used.
– Independently adjustable on and off delays are available per channel.
• Test outputs (digital input modules only)
– Separate test outputs are provided for short circuit detection of a safetyinput (or inputs).
– Power (24V) can be supplied to devices, such as safety sensors.
– Test outputs can be configured as standard outputs.
– Specific test outputs can be used for broken-wire detection of a mutinglamp.
keywords:1734 ib8s specifications;1734 ib8s price;1734 ib8s rockwell;rockwell 1734 ib8s;1734ib8s;ab 1734 ib8s;allen bradley 1734 ib8s;1734 ib8s
Professional Service Team
We are a leading PLC provider, supported by a dedicated team of commercial sales, warehouse, quality control, sourcing, and support professionals. We specialize in supplying original, brand-new PLC parts in factory-sealed packaging. Our extensive inventory and strong partnerships with leading express companies enable us to offer fast, worldwide shipping at competitive prices. We prioritize superior quality and aim to respond to inquiries within one business day. Orders are processed and shipped within 0-1 business days of full payment, with expedited shipping options available.
Is Allen Bradley 1734-IB8S not the part you are wanting?
Check out the rest of our website to see what else we have to offer!
Contact us directly, we will provide you with the most professional service.
✉ sales7@apterpower.com // ☏ +8618030175807 (Whatsapp)