Overview
The MVI71-MNET is a Modbus TCP / IP Interface module from Allen-Bradley's encompass partner company, Prosoft Technology. This module is a single slot module with ethernet application port supporting 10/100 MB transmission speed and a configuration serial port that supports RS232 electrical standard. This module supports explicit messaging through Block Transfer Read (BTR) and Block Transfer Write (BTW) with a variety of components including Modicon devices.

Technical specifications for MVI71-MNET
| Manufacturer | Rockwell Automation |
| Brand | Allen-Bradley |
| Part Number/Catalog No. | MVI71-MNET |
| Manufacturer | Prosoft Technology |
| Manufacturer: | Prosoft Technology |
| Product Type | Modbus TCP/IP module |
| Registers | 5000 |
| Communication ports: | One (1) RJ45 Ethernet port One (1) RS232 configuration port (CFG) |
| Supported function codes | 1, 2, 3, 4, 5, 6, 8, 15, 16, 17, 22 and 23 |
| Servers/Devices per Client Connection | 100 max. |
| Supported Modbus modes: | Master / Slave |
| No, of commands | 100 commands per port |
| Interface | 10/100 MB Ethernet-compatible |
| Module width: | Single slot |
| Communication Port: | Application port; Configuration port; Emulation port |
| Backplane Current Load | 800 mA @ 5V DC; 3 mA @ 24 VDC |
| Compatible backplane: | 1771 Backplane |
| Ethernet Data Transfer speed: | 10 / 100 mbps |
| Operating Shock | 30 G |
Description
The MVI71-MNET is manufactured by Prosoft Technology that is compatible for use with Allen-Bradley's PLC series. This module is specifically a Modbus TCP I/P interface module that supports Block Transfer read (BTR) and Block Transfer Write (BTW) for implementing explicit Modbus messaging. This module comes with an Ethernet application port that supports 10/100 Mbps and a configuration port that is compatible with the RS232 electrical standard used for module configuration. The MVI71-MNET is compatible with Modicon controllers, PLC5/E rev C/N, D/E, E/D, SLC5/05 series A, OS503 frn4, 1785-ENET Series A, rev D, Interchange V6.2, MicroLogix 1100/1400/ANY via 1761-NET-ENI, CompactLogix 1768-L43/L45 via 1768-ENBT, CompactLogix 1769-L32E/L35E/ANY, CompactLogix L23E, RSLinx Gateway V1.7+, and ControlLogix 1756-ENET/ENBT/EN2T/EN2TR. This module includes a powerful Modbus network analyzer and supports special Modbus functions such as command control, event commands, status, etc. It supports up to Five (5) independent server connections on port 502 and the same feature on port 2000. The user data memory of this module stores error codes, network error counters, and port status, which can be mapped and analyzed to determine the health and performance of the network. The MVI71-MNET can be installed in a remote or local rack. It is a single slot module that is installed at any available slot of the 1771chassis. It has a minimum response delay of 0 - 65535 msec; a response timeout of 1 - 65535 msec and a configurable retry count of 0-20. It allows command control from ladder logic and permits pass-through configuration. This module has a tertiary port that is capable of emulating channel 0 of the PLC.
Modbus Message Data
This new version of the module's program includes the pass-through mode. Inthis mode, write messages sent to a slave port are passed directly through to theprocessor. It is the responsibility of the ladder logic to process the messagereceived using this feature. If the side-connect interface is used, this data set willbe placed in the file selected in the SC_DATA.TXT file starting at register offset50. Ladder logic is required to parse the message or data set received and toplace the data in the correct user data file.If the block transfer interface is utilized, the pass-through messages will bepassed from the module to the processor in special control blocks. Ladder logicis required to handle each block received and to place the data in the correctuser data file.This information is passed from the module to the processor using a blockidentification code of 9996 if the unformatted pass-through mode (code 1) isselected. Word two of this block contains the length of the message and themessage starts at word 3. Other controller tags are required to store thecontrolled values contained in these messages. The Modbus protocol supportscontrol of binary output (coils - functions 5 and 15) and registers (functions 6 and16).Additionally, formatted message blocks can be sent from the module to theprocessor when the pass-through option is selected using the format selection(codes 2 or 3 in the MNET.CFG file). These blocks require less decoding thanthe unformatted blocks. Refer to the user manual for a full discussion on utilizingthe pass-through option in an application.
Related keywords: mvi71 mnet;Prosoft MVI71-MNET;MVI71-MNET pdf;MVI71-MNET datasheet;MVI71-MNET manual;MVI71-MNET sell
Experience the PLC Leader Advantage
- Your Dedicated Account Manager:
Enjoy personalized service from a single, highly trained account manager.
They understand your priorities: quality, competitive pricing, and rapid delivery.
Expect transparent, honest communication and prompt assistance for any inquiry.
- Unmatched Speed and Efficiency:
We prioritize your time with fast turnaround and accurate lead times.
Reliable, on-time delivery is our standard.
We coordinate with your preferred carrier and provide real-time tracking updates.
- Optimized Pricing Through Global Sourcing:
Benefit from our extensive inventory and strong partnerships with global manufacturers and suppliers.
We secure the most competitive pricing to meet your budget requirements.
Is Prosoft MVI71-MNET not the part you are wanting?
Check out the rest of our website to see what else we have to offer!
Contact us Anytime when you need!
➪Vicky
☏ +8618030175807(Whatsapp)