The General Electric IS220TTURH1C Terminal Board is an advanced component designed for use within industrial control systems, particularly within GE's Mark VIe and Mark VI control systems. As a high-performance terminal board, the IS220TTURH1C serves as a key component for interfacing control wiring with various field devices, ensuring secure and reliable connections for signal transmission and system monitoring.
Email: sales7@apterpower.com
Whatsapp: +8618030175807 (Phone)

Specifications

Part Number: IS220TTURH1C
Manufacturer: General Electric
Series: Mark VIe
Product Type: Terminal Board
Technology: Surface mount
Number of outputs: Generator breaker coil, 5A at 125 V dc
Power supply voltage: Nominal 125 V dc to breaker coil
MPU pulse rate range: 2 Hz to 20 kHz
With high-grade construction and precise engineering, the IS220TTURH1C offers unmatched reliability in both standard and critical control environments, such as power generation, petrochemical industries, and manufacturing. It simplifies the installation and maintenance of control systems, reduces wiring complexities, and enhances system performance. This terminal board ensures your system's seamless operation by providing clear, accessible, and secure electrical connections.
Features
Pulse Rate Devices: Equipped to handle inputs from 12 pulse rate devices. These devices are responsible for sensing a toothed wheel to measure the turbine's rotational speed. This information is crucial for monitoring and controlling the turbine's operational speed.
Voltage Signals: The board receives generator voltage and bus voltage signals taken from potential transformers. These signals provide essential data for voltage monitoring, ensuring the generator operates within safe voltage levels.
Main Breaker Coil Control: Offers a 125 V DC output that is used to control the main breaker coil for automatic generator synchronization. This feature is essential for ensuring the safe and synchronized operation of the generator.
Shaft Voltage and Current Sensors: Inputs from shaft voltage and current sensors are received by the board. These sensors play a critical role in measuring induced shaft voltage and current, which is vital for the turbine's health and safety monitoring.
Overspeed Trip Signals: Handles three overspeed trip signals that are sent to the trip board. These signals serve as a safety mechanism to detect and respond to turbine overspeed conditions.
Additional I/O Signals: In addition to the overspeed trip signals, the board accommodates various other input and output signals from the trip board, expanding its role in monitoring and controlling the turbine's operation.
Shaft Voltage AC Test and Sensor Inputs
The turbine control system, often utilized in the Mark VIe system, incorporates various tests and sensor inputs to ensure precise monitoring and control of critical components like shaft voltage and current, generator and bus voltages, and generator breaker circuits. These tests and inputs contribute to the efficient operation and safety of the system. Let's delve into the details of these components:
Test Voltage Application: A test voltage with a frequency of 1 kHz is applied to the input of the PTUR shaft voltage circuit, which is primarily part of the R module. This test voltage serves as a diagnostic measure to assess the integrity and functionality of the shaft voltage circuit.
Shaft Current Measurement: The system measures shaft current in amperes AC. This measurement is performed using a shunt voltage, with peak-to-peak voltage levels of up to 0.1 V. Accurate measurement of shaft current is crucial for assessing the health and safety of the turbine.
Potential Transformer Outputs: The system utilizes two single-phase potential transformers with secondary outputs supplying a nominal 115 V rms. These sensors are essential for monitoring generator and bus voltages. The reliable measurement of voltage levels is vital to ensure the safe operation of the generator.
Loading and Isolation: Each input from these sensors imposes a loading of less than 3 VA. Additionally, each PT (Potential Transformer) input is magnetically isolated with a 1,500 V rms barrier, ensuring the safety and integrity of the measurement process.
Cable Length: The system accommodates cable lengths of up to 1,000 feet, utilizing 18 AWG wiring for these sensor connections. This extended cable length capability provides flexibility in installation and system configuration.
Related words:is220tturh1c;GE IS220TTURH1C;IS220TTURH1C pdf;IS220TTURH1C datasheet;IS220TTURH1C manual
Reasons for Choosing us
1. Unmatched Product Quality:
Brand New & Factory Sealed: Every product you receive from us is guaranteed to be brand new, straight from the manufacturer, and factory sealed for optimal performance and reliability.
2. Unparalleled Speed & Reliability in Delivery:
Expedited Shipping Options: We prioritize getting your IS230TNTRH1C module to you quickly. Choose from a variety of expedited shipping options through trusted carriers like DHL, UPS, FedEx, and TNT to minimize downtime.
3. Comprehensive Warranty Coverage:
12-Month Warranty : We stand behind the quality of our products.
4. Secure & Flexible Payment Options:
100% T/T Payment: For in-stock items, we offer a secure 100% T/T payment option for a streamlined purchasing experience.
We're Open to Discussing Alternative Solutions: For specific needs or larger orders, we may be able to discuss alternative payment terms to best suit your requirements. Please contact us for more information.
Is General Electric IS220TTURH1C not the part you are wanting?
Check out the rest of our website to see what else we have to offer!
Send us the inquiry now,sales7@apterpower.com/+86 18030175807