When a ControlLogix 5570 controller must be replaced or specified for an existing machine, the catalog numbers 1756-L71, 1756-L72 and 1756-L73 can appear almost identical. They use the same ControlLogix chassis platform, support the same programming languages and share the same published maximum I/O capacity. The main hardware difference is user memory: 2 MB, 4 MB or 8 MB.
That difference matters, but selecting a controller only by choosing the largest memory size can waste budget without solving compatibility issues. Maintenance engineers and MRO buyers should first confirm the existing project size, firmware revision, catalog suffix, communication modules and future expansion requirements. This guide compares the three standard Logix5570 controllers and provides a practical selection checklist.
Quick answer
Choose the 1756-L71 for a verified project that fits comfortably within 2 MB. Choose the 1756-L72 when 4 MB provides the right balance between present requirements and expansion margin. Choose the 1756-L73 for larger applications that need up to 8 MB for additional code, tags, data structures, alarms or future modifications. Memory is the primary published difference among these three standard controllers; it does not change their maximum rated I/O count.
|
2 MB
1756-L71 User Memory
|
4 MB
1756-L72 User Memory
|
8 MB
1756-L73 User Memory
|
500
Shared Max Connections
|
1756-L71 vs 1756-L72 vs 1756-L73: Specification Comparison
All three products belong to the Allen-Bradley ControlLogix 5570 family. The values below are based on Rockwell Automation publication 1756-TD001W-EN-P, dated October 2025.
| Specification | 1756-L71 | 1756-L72 | 1756-L73 |
|---|---|---|---|
| User memory | 2 MB | 4 MB | 8 MB |
| I/O memory | 0.98 MB | ||
| Nonvolatile storage | 1 GB 1784-SD1 Secure Digital card supplied preinstalled | ||
| Maximum digital I/O | 128,000 | ||
| Maximum analog I/O | 4,000 | ||
| Maximum controller connections | 500 | ||
| Built-in port | One USB 2.0 port for temporary local programming, configuration, firmware updates and online edits | ||
| Backplane current | 800 mA at 5.1V DC; 5 mA at 1.2V DC | ||
| Power dissipation | 2.5 W | ||
| Slot width / approximate weight | One slot / 0.25 kg (0.55 lb) | ||
| Standard operating temperature | 0 to 60°C (32 to 140°F) | ||
The table makes the purchasing decision clearer: the 1756-L71, 1756-L72 and 1756-L73 share the same I/O ratings, physical slot requirement, electrical load and standard environmental range. Increasing the catalog number from L71 to L73 primarily increases the available user memory.
What These Three ControlLogix Controllers Have in Common
The same Logix5570 architecture
Each controller supports relay ladder logic, structured text, function block diagrams and sequential function charts. Rockwell Automation specifies up to 32 controller tasks and full controller redundancy support for the Logix5570 family. Integrated motion can be implemented through supported interfaces and networks.
The same chassis-based design
The controllers occupy one slot and can be installed in any slot of a compatible ControlLogix chassis. Supported standard chassis include the 1756-A4, A7, A10, A13 and A17 families and their listed coated variants. Multiple controllers may also be installed in the same chassis when the application architecture requires it.
The same communication approach
The front USB port is a temporary engineering connection, not a permanent industrial network port. EtherNet/IP, ControlNet, DeviceNet and other network communications require the appropriate communication interface module in the local chassis. When comparing replacement CPUs, also check the installed network bridge-for example, a 1756-EN2x or 1756-ENBT-and confirm its supported connections and firmware compatibility.
Energy storage instead of a conventional controller battery
Standard 1756-L7 controllers ship with a capacitor-based 1756-ESMCAP energy storage module and use an SD card for nonvolatile storage. This is an important distinction from older Logix5560 controllers that used lithium batteries. If a replacement request mentions a BAT indicator or battery part number, verify whether the installed controller is actually an L6x rather than an L7x.
The Main Difference: 2 MB, 4 MB or 8 MB of User Memory
User memory stores controller logic, tags, Add-On Instructions, data structures, alarms, recipes and other project content. The correct choice depends on the actual memory used by the application-not simply on the number of physical I/O modules in the chassis.
|
LEAN PROJECT
1756-L71
Best for a verified project that fits comfortably within 2 MB and has limited expansion requirements.
|
BALANCED CHOICE
1756-L72
A practical 4 MB middle tier for current requirements plus moderate future program growth.
|
EXPANSION READY
1756-L73
The strongest of the three for large applications, complex data and substantial planned modifications.
|
When the 1756-L71 is the right choice
The Allen-Bradley 1756-L71 provides 2 MB of user memory. It is usually the most economical selection when replacing an existing L71 with a confirmed project that has comfortable unused memory.
It can suit individual machines, packaging cells, material-handling systems and moderate discrete-control applications. Before choosing it for a new or expanded system, check the controller properties in Studio 5000 and leave space for commissioning changes, new tags, troubleshooting logic and later equipment additions. A project that only barely fits today has little maintenance margin.
When the 1756-L72 is the best balance
The 1756-L72 ControlLogix controller doubles user memory to 4 MB while retaining the same physical and electrical platform specifications. It is often the practical middle option for a project that has outgrown 2 MB or needs reasonable capacity for planned modifications.
The L72 is a strong fit for multi-cell production areas, medium process applications or systems with a growing tag database, more communication messages and reusable program structures. Buyers should still review actual project memory rather than assuming 4 MB is automatically sufficient.
When the 1756-L73 is worth selecting
The 1756-L73 provides 8 MB of user memory. It is the better choice when a verified project already exceeds the L72 capacity or when an engineering plan requires substantial growth. Typical reasons include additional production areas, extensive equipment modules, larger data structures, more recipes and alarms, complex sequencing or long-term program expansion.
The L73 does not increase the published maximum digital or analog I/O count compared with the L71 and L72. Its advantage is application capacity. For the complete family overview, see the Allen-Bradley 1756 ControlLogix controller selection guide.
Do Not Select a Replacement by Memory Alone
A controller with more memory is not automatically a plug-and-play replacement. Complete the following checks before removing the existing CPU or ordering a spare:
- Record the complete catalog number. Standard L71/L72/L73 controllers are different from GuardLogix safety models ending in "S," conformal-coated models ending in "K" and the extended-temperature 1756-L73XT. Do not treat these suffixes as optional.
- Check project memory use. Open the existing project in the correct Logix Designer environment and record used and available controller memory. Include a sensible expansion margin.
- Verify controller series and firmware. Record the Series letter and installed firmware revision from the controller label, project properties or diagnostic tools. Confirm the target revision in Rockwell Automation's Product Compatibility and Download Center.
- Confirm the programming software version. A project must be compatible with the firmware loaded into the replacement controller. Plan any firmware flash and project conversion before the shutdown window.
- Audit the chassis and power budget. Confirm the chassis catalog number and calculate the combined backplane current of the CPU, network modules and I/O modules.
- Review the communication architecture. The L7x controller does not provide a built-in permanent Ethernet port. Identify all Ethernet, ControlNet, DeviceNet or other communication modules and check their revisions.
- Back up the application and nonvolatile image. Save a verified project copy, document the slot configuration and review SD-card load settings before powering down.
- Confirm condition and included accessories. For a spare controller, request clear label photos, Series and revision information, condition, warranty, SD-card status and energy-storage-module details.
Maintenance note: Never flash firmware or replace a production controller without a verified backup and an approved recovery procedure. The correct shutdown, lockout/tagout and commissioning process depends on the machine and site.
Practical Selection Examples
Replacing a failed 1756-L71
If the existing project ran reliably on an L71 and no expansion is planned, another L71 normally preserves the original memory class and reduces unnecessary change. Match the complete catalog suffix, Series and firmware requirements. If the project is approaching the 2 MB limit, an L72 or L73 may offer more capacity, but the change should be reviewed and tested as a controlled engineering modification.
Expanding an existing line
When new stations, recipes, alarms or reusable code blocks will be added, calculate the projected memory requirement before selecting the CPU. The L72 provides twice the L71 memory; the L73 provides four times the L71 memory. Choosing adequate headroom during a planned expansion is usually less disruptive than replacing the controller again after commissioning.
Keeping a critical spare
A plant-wide spare strategy should be based on installed catalog numbers and validated restore procedures. One higher-memory controller may potentially support several standard L7x applications, but only after firmware, Series, project and network compatibility are confirmed. Store the approved project backup and recovery instructions with the spare-parts record.
Frequently Asked Questions
Can a 1756-L73 replace a 1756-L71?
They belong to the same ControlLogix 5570 family and share the same one-slot chassis format, but the replacement should not be assumed to be automatic. Verify the project, controller definition, firmware revision, communication modules and commissioning procedure before making the change.
Does the 1756-L73 support more I/O than the 1756-L71?
No. Rockwell Automation publishes the same maximum ratings for these models: 128,000 digital I/O, 4,000 analog I/O and 128,000 total I/O. The L73 provides more user memory for the application.
Do the 1756-L71, L72 and L73 have built-in Ethernet?
No permanent Ethernet port is built into these standard Logix5570 CPUs. Their built-in USB port is intended for temporary local programming and maintenance. Add the appropriate ControlLogix communication module for EtherNet/IP or another required network.
Do Logix5570 controllers require a lithium battery?
Standard L7x controllers use an energy storage module rather than the battery arrangement found on older L6x processors. They also support SD cards for nonvolatile storage.
Is the 1756-L71S the same as the 1756-L71?
No. The 1756-L71 is a standard ControlLogix controller, while the 1756-L71S is a GuardLogix safety controller used with the required safety architecture. Safety and standard catalog numbers must not be substituted without a qualified safety-system review.
Final Recommendation
For a verified application that fits comfortably within 2 MB, the 1756-L71 is the straightforward choice. The 1756-L72 offers a practical 4 MB middle tier for systems that need more space and moderate expansion capacity. The 1756-L73 is the strongest option of the three for large 8 MB projects and substantial future growth.
The safest purchasing decision begins with the installed controller label and a checked project backup. Send the complete part number, suffix, Series, firmware revision, quantity and destination when requesting a quotation. If this is a replacement, include a clear nameplate photo and the existing controller details.
Related reading: How to Fix Common Fault Codes on Allen-Bradley 1756 ControlLogix Processors
Technical reference: Rockwell Automation, ControlLogix and GuardLogix Controllers Technical Data, publication 1756-TD001W-EN-P, October 2025. Always verify the latest product documentation and compatibility information before engineering or purchasing decisions.
PLC Leader is an independent supplier and is not an authorized distributor or representative of Rockwell Automation. Allen-Bradley, ControlLogix, GuardLogix, Logix5570, Studio 5000 and related marks belong to their respective owners and are used for product identification only.
| 18-06-18-00/01 | 180-MF2-40-020-000 | 1FK2104-4AF10-1MB0 |
| 6GK1143-0TB01 | 6NH1802-0BA | 6SL3210-1KE23-8AF1 |
| 961264-135 | AS5918L4204-ENM24 | Barmag HC-ED421-002 |
| Beckhoff AX 5901-0000 | Beckhoff EL3202-0010 | BKO-C2473 |
| BOD 66M-RB11-S92 | BSM90B-1150AX | BZ16-03T 1355624 |
| CM200 | CM442-2ER8/0 | CP95NDB100-200 + C95N100D-UA |
| CWEA-LIN | EBX 200-T 054914-109 | EK1310 |
| FA37B/R CMPZ71S/KY/AK0H/SM1 | GBK24/06 | H-4WEH 16 HT60/6AG24NS2Z4 |
| KA47 DRN80M4/BE1/TH | Krauss Maffei LVR 10 | Laipple KEB NMS40 |
| LK6-1365/7C/16/40A/43/44/57 | MSS80c4 | N3R252-08E4 |
| PGF2-22/011RH01VE4 DE100LB4 | PLQE060-032-SFSB3AC-E9 | S203VG-6830-D63K8B |
| S30B-3011CA 1056428 | SCPi 20 IMP RD M12-5 | SE-C4.170.030-14.000 IND-000 |
| Siemens 1FT6105-1AC71-4AG1 | Siemens 6ES5 464-8MF21 | Siemens 6ES7518-4FP00-0AB0 |
| Siemens 9AC9100-0AA01 | SLG 420-E0800-03-RFH | SM031HZ-(i=12) |
| STS-550C | TS 422-10yt | WTS112 |