Bently Nevada 330103-01-04-10-02-05 3300 XL 8 mm Probe

• Bently Nevada 330103-01-04-10-02-05 probe
• 3300 XL 8 mm metric probe without armor
• M10 x 1 thread; 15 mm max engagement
• AA01: 10 mm unthreaded section
• BB04: 40 mm overall case length
• CC10: nominal 1.0 m total probe length
• DD02 ClickLoc; EE05 CSA, ATEX, IECEx option
Send Inquiry
Description

330103-01-04-10-02-05 Short-Case Proximity Probe

Bently Nevada 330103-01-04-10-02-05 is a 3300 XL 8 mm proximity probe with an M10 x 1 metric threaded case and an unarmored lead. Its metal case is 40 mm long, including a 10 mm unthreaded section at the sensing end.

The probe has a nominal 1.0 m total length, a DD02 standard cable with ClickLoc connector, and the EE05 CSA, ATEX and IECEx approval option. The short case requires suitable mounting reach and adjustment clearance.

40 mm BB04 overall case length
10 mm AA01 unthreaded portion
1.0 m CC10 nominal total probe length

40 mm Case Geometry and Thread Engagement

The AA01 and BB04 dimensions define a compact metric case. Its 10 mm unthreaded portion and 40 mm overall length leave a 30 mm difference between the two specified dimensions.

AA01 / BB04 Case Dimensions
 
 
10 mm AA01: Unthreaded length
40 mm BB04: Overall case length
40 − 10 = 30 mm Dimensional difference, not permissible thread engagement

Simplified illustration only; not to scale or a machining drawing.

M10 x 1 Engagement Is Limited to 15 mm

The manufacturer specifies a maximum thread engagement of 15 mm for M10 x 1 proximity probe cases. Engagement beyond this limit may cause binding during installation.

Mounting requirement: Do not use the 30 mm dimensional difference as an engagement limit. Confirm the holder's thread depth, mechanical clearance and available adjustment before setting the probe gap.

40 mm Versus 70 mm 330103 Probe Cases

The 330103-02-07-10-02-00 shares the M10 x 1 unarmored probe family, DD02 connector and nominal 1 m length. Its case is 70 mm overall, compared with 40 mm for this configuration.

BB04 Current
40 mm
BB07 Related
70 mm
30 mm Shorter Difference in overall metal case length
Feature 330103-01-04-10-02-05 330103-02-07-10-02-00
Unthreaded section 10 mm (AA01) 20 mm (AA02)
Overall case 40 mm (BB04) 70 mm (BB07)
Nominal total probe length 1.0 m 1.0 m
Connector DD02 ClickLoc DD02 ClickLoc
Approval option EE05: CSA, ATEX, IECEx EE00: Not required

Which Case Fits the Mounting Holder?

A short case may leave insufficient insertion reach where the original holder was designed for a longer probe. Conversely, a longer case may interfere with surrounding hardware or limit adjustment.

The correct replacement must provide the required tip position while maintaining appropriate thread engagement. Equal electrical length does not establish mechanical interchangeability.

330103-01-04-10-02-05 Ordering Specifications

Ordering Code Field Specification
330103 Probe family 3300 XL 8 mm, M10 x 1 thread, without cable armor
AA = 01 Unthreaded length 10 mm
BB = 04 Overall case length 40 mm
CC = 10 Total probe length Nominal 1.0 m
DD = 02 Connector and cable Miniature coaxial ClickLoc connector, standard cable
EE = 05 Agency approval CSA, ATEX and IECEx approval option

Bently Nevada 3300 XL 8 mm Proximity Transducer Datasheet

330103 Standard Cable and EE05 Approval Option

Bently Nevada 330103 series M10 x 1 unarmored proximity probe and standard cable, related family construction reference

330103 series reference: 330103-02-07-05-02-05. The illustrated variant has a 20 mm unthreaded section, a 70 mm case and a 0.5 m nominal probe length. DD02 and EE05 match the listed configuration.

DD02 Standard ClickLoc Connection

The 330103 family uses an unarmored probe cable. The selected DD02 option has a miniature coaxial ClickLoc connector with standard cable.

DD01 is the alternative standard-cable option with a connector protector. A separate FluidLoc option is required when that cable construction is specified.

EE05 Agency Approvals

EE05 selects the manufacturer's CSA, ATEX and IECEx approval option. The actual supplied item's markings and certificate conditions must meet the installation requirements.

EE00 is the separate ordering option where agency approval is not required. It must not be treated as equivalent to EE05 for a site that requires certified equipment.

1.0 m Probe and 330180 Proximitor Matching

The CC10 option provides a nominal 1.0 m complete probe assembly. A matching 1 m 330180 Proximitor is used for the corresponding 3300 XL 8 mm transducer system.

330103-01-04-10-02-05 Nominal 1.0 m probe
→
330180 Proximitor Matching 1 m system configuration

Direct probe-to-Proximitor connection for the nominal 1 m system; no extension cable required.

The 330180 one-metre mounting selections include option 10 for panel mounting, 11 for DIN mounting, and 12 without mounting hardware. The Proximitor approval option is selected separately.

System compatibility: A matching electrical length does not remove the need to confirm the installed Proximitor, probe gap, cable configuration and approval requirements.

330103-01-04-10-02-05 Frequently Asked Questions

Is BB04 one of the shorter M10 x 1 probe cases? +

Yes. BB04 specifies a 40 mm overall case for the standard M10 x 1 probe family. It is shorter than configurations such as BB07 at 70 mm. The correct length depends on the mounting arrangement.

How does AA01 affect the probe mounting position? +

AA01 specifies a 10 mm unthreaded section. This determines the smooth portion of the probe case near the sensing end. The holder and mounting position must accommodate that section.

Does the 30 mm case difference allow 30 mm of thread engagement? +

No. Subtracting the 10 mm unthreaded section from the 40 mm overall case gives a geometric difference of 30 mm. The manufacturer separately limits M10 x 1 thread engagement to 15 mm.

Can a 70 mm case replace the 40 mm version? +

Not automatically. The 70 mm BB07 case is 30 mm longer. The related AA02 configuration also has a 20 mm unthreaded section, rather than 10 mm. Verify holder depth, clearance and adjustment travel before substitution.

What should be checked when installing this short case? +

Confirm the M10 x 1 mounting thread, 40 mm case reach, maximum 15 mm thread engagement, clearance around the holder and the required probe-to-target gap. Follow the approved 3300 XL installation procedure.

Does the 1.0 m probe need an extension cable? +

No additional extension cable is needed for a nominal 1 m 3300 XL system. The CC10 probe connects directly to a matching 1 m 330180 Proximitor.

Can an EE00 probe replace this EE05 configuration? +

Not where the installation requires the approvals associated with EE05. EE00 is the option where agency approval is not required. Confirm the appropriate markings and certificates before replacing a certified probe.

Related Bently Nevada 3300 XL Components

Request 330103-01-04-10-02-05 Availability

Request the exact Bently Nevada 330103-01-04-10-02-05 short-case metric probe with 1.0 m total length, DD02 ClickLoc connector and EE05 approval option.

Include the quantity, preferred condition, destination country and original probe identification. For a replacement, the mounting holder dimensions and installed Proximitor model help confirm compatibility.

Request a 330103 Short-Case Quote

Hot Tags: 330103-01-04-10-02-05, Bently Nevada 330103, 3300 XL 8 mm probe, 40 mm proximity probe, M10 x 1 probe, short case proximity sensor, EE05 approvals, 330103 short-case metric probe, 3300 XL 8 mm proximity probe, 330103 70 mm case probe, M10 x 1 unarmored probe, 330103 1 m probe replacement, EE05 approved proximity probe

Hot Tags: 330103-01-04-10-02-05, Bently Nevada 330103, 3300 XL 8 mm probe, 40 mm proximity probe, M10 x 1 probe, short case proximity sensor, EE05 approvals, generator monitoring, gas sensor, power quality analyzer, process monitoring, data driven maintenance, power supplies for industrial equipment

Disclaimer:

PLCleader sells new and surplus products and develops channels for purchasing such products. This website has not been approved or recognized by any of the listed manufacturers or trademarks.

PLCleader is not an authorized distributor, dealer, or representative of the products displayed on this website. All product names, trademarks, brands, and logos used on this website are the property of their respective owners. The description, explanation, or sale of products with these names, trademarks, brands, and logos is for identification purposes only and is not intended to indicate any association with or authorization from any rights holder.